![Brother FAX-8650P Service Manual Download Page 133](http://html.mh-extra.com/html/brother/fax-8650p/fax-8650p_service-manual_53583133.webp)
V
- 46
WSW36
(Function setting 14)
Selector
No.
Function
Setting and Specifications
1
ECP* mode
0:
ON
1:
OFF
2
Recovery from Inactive PC
Interface
0:
Disabled
1:
Enabled
3
PC Power-off Recognition Time
0:
Normal
1:
Long
4
Not used.
5
Escape from Phase C
0:
Yes
1:
No
6
|
8
Lower limit of frequency to be
ignored after detection of calling
signals (Ci)
No. 6 7 8
0 0 0 :
0 (Not ignored)
0 0 1 :
4 (448 Hz)
0 1 0 :
8 (244 Hz)
0 1 1 :
12 (162 Hz)
1 0 0 :
16 (122 Hz)
1 0 1 :
20 (97 Hz)
1 1 0 :
24 (81 Hz)
1 1 1 :
28 (69 Hz)
*ECP (Enhanced Capabilities Port)
l
Selector 1:
ECP mode
The ECP mode enhances the normal bidirectional communications between the facsimile
equipment and the connected PC for higher transmission speed.
l
Selector 2:
Recovery from Inactive PC Interface
If the facsimile equipment recognizes via the STB signal line that the connected PC is powered
off, it will turn the PC interface outputs Low to protect the PC from hazards that could be caused
by weak electric current accidentally flown from the equipment.
This selector determines whether the equipment should recover from the inactive PC interface to
normal interfacing state upon receipt of data from the PC.
l
Selector 3:
PC Power-off Recognition Time
This selector sets the time length from when the equipment detects the PC powered off until it
recognizes the detected state as power-off.
If selector 2 is set to "0," it is recommended that selector 3 be set to "1": otherwise, the equipment
may mistakenly detect PC powered off.
l
Selector 5:
Escape from Phase C
This selector determines whether or not the equipment will escape from phase C when it detects
an RTC (Return to Control) in non-ECM mode or an RCP (Return to Control Partial page) in ECM
mode.
l
Selectors 6 through 8: Lower limit of frequency to be ignored after detection of calling signals (Ci)
At the start of reception, if the equipment detects the frequency of calling signals (Ci) specified by
selectors 1 through 4 of WSW14, it will start the ringer sounding. When doing so, the equipment
may fail to detect the calling signals normally due to noises superimposed at the time of reception.
To prevent it, use selectors 6 through 8 of WSW36.
If the equipment detects higher frequencies than the lower limit specified by these selectors, it will
regard them as noise and interpret that detecting state as being normal, allowing the ringer to keep
sounding (until the equipment starts automatic reception of FAX data if in the FAX mode or enters
the TAD mode if set in the TEL mode, according to the preset number of ringers).
Summary of Contents for FAX-8650P
Page 1: ...FACSIMILE EQUIPMENT SERVICE MANUAL MODEL FAX3750 FAX 8650P MFC7750 ...
Page 5: ...CHAPTER I GENERAL DESCRIPTION ...
Page 12: ...CHAPTER II INSTALLATION ...
Page 13: ...CONTENTS 1 INSTALLING THE UPDATE DATA TO THE FACSIMILE EQUIPMENT II 1 ...
Page 16: ...CHAPTER III THEORY OF OPERATION ...
Page 18: ...III 1 1 OVERVIEW Not provided on the FAX 8650P ...
Page 28: ...III 11 Not provided on the FAX 8650P Location of Sensors and Actuators ...
Page 31: ...III 14 Main PCB Modem PCB ...
Page 36: ...CHAPTER IV DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 42: ...IV 4 n n Disassembly Order Flow ...
Page 71: ...IV 33 1 Provided on the FAX 8650P 2 Not provided on the FAX 8650P ...
Page 72: ...IV 34 Setting up the main PCB after replacement ...
Page 84: ...IV 46 2 Control panel locks 3 Scanner frame ASSY and separation roller gear ...
Page 85: ...IV 47 4 Top cover lock spring 5 Gear drive unit ...
Page 86: ...CHAPTER V MAINTENANCE MODE ...
Page 93: ...V 6 Scanning Compensation Data List ...
Page 141: ...V 54 FAX3750 FAX 8650P MFC7750 Key Button Entry Order ...
Page 146: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Page 171: ...Oct 98 SM5X5303 Printed in Japan ...
Page 172: ...FAX3750 FAX 8650P MFC7750 Appendix 1 EEPROM Customizing Codes ...
Page 194: ......
Page 195: ......
Page 196: ......