9-17
Confidential
9.2.4 Troubleshooting
Procedures
[ 1 ] Control panel related
Trouble Check:
(1) LCD shows nothing.
• Panel-main harness between the main PCB and the control
PCB
• Interfaces between the main PCB and power supply PCB
• LCD
• LCD flat cable
• Control panel PCB
• Power supply PCB
• Main PCB
(2) Control panel inoperative.
• Panel-main harness between the main PCB and the control
PCB
• Interfaces between the main PCB, and power supply PCB
• Control panel PCB
• Rubber keypad
• Main PCB
Summary of Contents for FAX-545
Page 7: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 18: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 26: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 33: ...3 6 Confidential Not provided on the FAX T102 Sensors and Actuators Locations ...
Page 35: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 38: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 81: ...5 41 Confidential 5 1 17 Routing of the Harnesses 0 11 ...
Page 83: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 88: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 95: ...8 6 Confidential Scanning Compensation Data List a b c d e f g h i j k ...
Page 113: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 116: ...9 2 Confidential ...
Page 117: ...9 3 Confidential ...
Page 185: ......
Page 186: ......
Page 187: ......
Page 189: ......
Page 190: ......
Page 191: ......
Page 192: ......
Page 193: ......
Page 194: ......
Page 198: ...Confidential August 08 SM FAX034 8X4600 7 Printed in Japan ...