3-115
Confidential
9.43 MP paper empty sensor PCB ASSY / MP paper empty
actuator 1 / MP paper empty actuator 2
(1) Remove the five taptite bind B M4x12 screws. Remove the main frame R from the paper
feed frame ASSY, and pull out the low-voltage power supply harness from the hole of the
main frame R.
Fig. 3-116
Taptite bind B M4x12
Main frame R
Low-voltage power supply harness
Hole
Paper feed frame ASSY