![Brother DCP-L3510CDW Service Manual Download Page 409](http://html.mh-extra.com/html/brother/dcp-l3510cdw/dcp-l3510cdw_service-manual_53471409.webp)
5-81
Confidential
1.3.36 Reset counters for consumable parts (Function code 88)
< Function >
This function is performed to reset the counter for each consumable part in the main PCB after
that has been replaced.
< Operating Procedure >
(1) For models with touch panel
Press the [8] twice in the initial state of maintenance mode. “Reset-Fuser Unit” is
displayed on the LCD.
For models without touch panel
Press the [
▲
] or [
▼
] in the initial state of maintenance mode to display
“MAINTENANCE 88” on the LCD, and press the [OK]. “Reset-Fuser Unit” is displayed
on the LCD.
(2) Press the [
▲
] or [
▼
] to display the part with the counter to be reset on the LCD, and press
the [Start] or [Mono Start].
Enter the type selection of fuser unit only when the “Reset-Fuser Unit” is selected. After
selecting the “Reset-Fuser Unit”, press the [
▲
] or [
▼
] to select the last digit value of the
serial number of fuser unit, and press the [Start] or [Mono Start].
(3) “*******OK?” is displayed on the LCD. Press the [Start] or [Mono Start] to reset the counter
for the selected part and return the display to the procedure (2). (******* represents the
name of the selected part)
(4) Press the [X] or [Stop], and the machine returns to the initial state of maintenance mode.
Selectable parts are shown in the table below.
Error display
Part name
Counter to be reset
Reset-Fuser Unit
Fuser unit
Printed pages counter
Reset-PF Kit T1
PF kit 1
Printed pages counter
Reset-PF Kit MP
PF kit MP
Printed pages counter
Reset-LVPS
Low-voltage power supply
PCB
Irregular power supply detection
counter
Summary of Contents for DCP-L3510CDW
Page 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Page 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Page 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Page 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Page 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Page 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...