2-37
Confidential
■
Error code 1A
Condensation occurred on the laser unit.
<User Check>
- Open the front and rear covers and leave them for 30 minutes or more with the power ON.
After that, close the front and rear covers and turn OFF and ON the power switch.
Error code 1B (C)
Error code 1C (M)
Error code 1D (Y)
Drum error. (An drum error occurred after the counter value exceeded the value more than
twice as long as the life of the drum.) (Printing is not available until the drum unit is replaced.)
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
Condensation
Leave switched ON. Fully open the front cover. Wait 30 minutes, switch OFF
and close cover, then switch ON.
Step
Cause
Remedy
1
Engine PCB failure
Replace the engine PCB ASSY.
2
Main PCB failure
Replace the main PCB ASSY.
Drum Stop
We cannot guarantee the print quality. Replace the Drum Unit. Refer to the
User’s Guide for instructions.
Drum Stop
We cannot guarantee the print quality. Replace the Drum Unit. Refer to the
User’s Guide for instructions.
Drum Stop
We cannot guarantee the print quality. Replace the Drum Unit. Refer to the
User’s Guide for instructions.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-9055CDN
Page 21: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 36: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 46: ...2 8 Confidential ADF part A4 model Fig 2 6 Left side Right side Document feed path Face up ...
Page 47: ...2 9 Confidential ADF part Legal model Fig 2 7 Left side Right side Document feed path Face up ...
Page 178: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Page 206: ...3 25 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Page 207: ...3 26 Confidential Disassembly Re Assembly second 5 ...
Page 381: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 397: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 405: ...5 6 Confidential Black and white scanning First side Fig 5 1 ...
Page 406: ...5 7 Confidential Black and white scanning Second side Fig 5 2 ...
Page 407: ...5 8 Confidential Color scanning First side Fig 5 3 ...
Page 408: ...5 9 Confidential Color scanning Second side Fig 5 4 ...
Page 433: ...5 34 Confidential Cover page sample Fig 5 17 End page sample Fig 5 18 ...
Page 440: ...5 41 Confidential Inter color position alignment adjustment chart Fig 5 22 ...
Page 447: ...5 48 Confidential Fig 5 25 ...
Page 450: ...5 51 Confidential Color test pattern Fig 5 27 MCYK Y C K M YCMK_ _A ...
Page 470: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 472: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Page 473: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Page 474: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Page 475: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 476: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 477: ...6 6 Confidential NCU PCB Circuit Diagram U S A Canada ...
Page 478: ...6 7 Confidential NCU PCB Circuit Diagram Europe Oceania ...
Page 479: ...6 8 Confidential NCU PCB Circuit Diagram China Asia South Africa Gulf ...
Page 481: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 523: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 527: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Page 531: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...