![Brother DCP 8060 Servise Manual Download Page 415](http://html.mh-extra.com/html/brother/dcp-8060/dcp-8060_servise-manual_53143415.webp)
App.
4-16
Confidential
WSW12
(Signal detection condition setting)
Selector
No.
Function
Setting and Specifications
1
2
Min. detection period required
for interpreting incoming
calling signal (CI) as OFF
No. 1
2
0
0
:
1500 ms
0 1 : 500
ms
1 0 : 700
ms
1 1 : 900
ms
3
4
Max. detection period for
incoming calling signal (CI)
being OFF
No. 3
4
0
0
: 6 sec.
0
1
: 7 sec.
1
0
: 9 sec.
1 1 : 11
sec.
5
6
Min. detection period required
for acknowledging incoming
calling signal (CI) as ON
No. 5
6
0
0
: 800 ms (1000 ms*)
0 1 : 200
ms
1 0 : 250
ms
1 1 : 150
ms
7
Line connection timing
(Not used.)
0:
Ringer-OFF 1:
Ringer-ON
period
(default)
period
8 Not
used.
*1000 ms in Chinese models.
- Selectors 1 through 4: Min. detection period required for interpreting incoming calling signal (CI) as
OFF
Max. detection period for incoming calling signal (CI) being OFF
If the machine detects the OFF state of a CI signal for the period greater than the value set by
selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the CI signal as OFF.
- Selectors 5 and 6: Min. detection period required for acknowledging incoming calling signal (CI) as ON
These selectors set the period required to make the machine acknowledge itself to be called. That
is, if the machine continuously detects a CI signal with the frequency set by selectors 1 through 4
on WSW14 during the period set by these selectors 5 and 6, then it acknowledges the call.
Summary of Contents for DCP 8060
Page 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 95: ...Confidential 4 2 Cover page sample End page sample ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 292: ...Confidential CHAPTER 7 CLEANING ...
Page 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Page 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Page 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 458: ...B Power Supply PCB 100V Confidential ...
Page 459: ...B Power Supply PCB 200V Confidential ...
Page 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...