![Brother DCP 8060 Servise Manual Download Page 412](http://html.mh-extra.com/html/brother/dcp-8060/dcp-8060_servise-manual_53143412.webp)
App.
4-13
Confidential
WSW09
(Protocol definition 1)
Selector
No.
Function
Setting and Specifications
1
Frame length selection
0: 256 octets 1: 64 octets
2
Use of non-standard
commands
0:
Allowed 1:
Prohibited
3
4
No. of retries
No. 3 4
0 0 :
4
times
0 1 :
3
times
1 0 :
2
times
1 1 :
1
time
5
T5 timer
0: 300 sec.
1: 60 sec.
6
T1 timer
0: 35 sec.
1: 40 sec.
7
8
Timeout for response from
the called station in
automatic sending mode
No. 7 8
0 0
: 55 sec. (in U.S.A. and Canada
models)
60 sec. (in other models)
0
1
:
140
sec.
1 0
: 90 sec.
1 1
: 35 sec.
NOTE:
Selectors 1 through 5 are not applicable in those models which do not support ECM.
- Selector 1: Frame length selection
Usually a single frame consists of 256 octets (1 octet = 8 bits). For communications lines with
higher bit error rate, however, set selector 1 to "1" so that the machine can divide a message into
64-octet frames.
Remarks
: The error correction mode (ECM) is a facsimile transmission manner in which the
machine divides a message into frames for transmission so that if any data error occurs
on the transmission line, the machine retransmits only those frames containing the error
data.
- Selector 2: Use of non-standard commands
If this selector is set to "0," the machine can use non-standard commands (the machine’s native-
mode commands, e.g., NSF, NSC, and NSS) for communications. If it is set to "1," the machine
will use standard commands only.
- Selectors 3 and 4: No. of retries
These selectors set the number of retries in each specified modem transmission speed.
- Selector 5: T5 timer
This selector sets the time length for the T5 timer.
- Selector 6: T1 timer
This selector sets the time length for the T1 timer.
- Selectors 7 and 8: Timeout for response from the called station in automatic sending mode
If the machine (calling station) receives no response (no G3 command) from the called terminal in
automatic sending mode for the period specified by these selectors, it disconnects the line.
Summary of Contents for DCP 8060
Page 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 95: ...Confidential 4 2 Cover page sample End page sample ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 292: ...Confidential CHAPTER 7 CLEANING ...
Page 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Page 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Page 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 458: ...B Power Supply PCB 100V Confidential ...
Page 459: ...B Power Supply PCB 200V Confidential ...
Page 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...