4-13
Confidential
4.
IF YOU REPLACE THE FB UNIT
■
Acquisition of White level data and set the CIS scanner area
(1) Press the buttons in the following order Menu, Start and the
button four times to
make the machine enter the maintenance mode. (Refer to
Maintenance Mode" in Chapter 5.
)
(2) MFC 7840W/7840N/7450/7440N/7340/7320
Press the 5 button twice.
DCP 7045N/7040/7030
Press the
or
button several times. "MAINTENANCE 55" appears on the LCD,
and then press the OK button. "Press START" appears on the LCD
.
(3) Press the Start button.
The white level data will be acquired automatically.
(4) If the procedure is completed, the machine will automatically return to the initial stage
of the maintenance mode.
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...