3-71
Confidential
9.18 Fuser unit
(1) Release the Fuser unit heater harness from the securing fixtures, and disconnect it from
the LVPS-heater harness.
Fig. 3-64
Harness routing: Refer to
.
(2) Disconnect the Center thermistor harness ASSY and the Side thermistor harness ASSY
from the Eject sensor PCB ASSY.
(3) Release the Center thermistor harness ASSY and the Side thermistor harness ASSY from
the securing fixtures.
Fig. 3-65
Harness routing: Refer to
.
LVPS-heater harness
Fuser unit heater harness
<Back side>
Side thermistor
harness ASSY
Center thermistor
harness ASSY
Eject sensor PCB ASSY
<Back side>
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...