3-28
Confidential
9.5 Front cover ASSY / Support flap
Manual feed models
(1) Open the Front cover ASSY.
(2) Remove the Collar 4 to remove the Develop joint link from the Front cover ASSY.
(3) Lift the Rib on the Front chute ASSY, and slide the Front cover ASSY in the direction of the
arrow A to remove it.
Fig. 3-13
Rib
Front chute ASSY
Develop joint link
Front cover ASSY
A
Collar 4
Summary of Contents for DCP-2537DW