2-105
Confidential
4.11 Troubleshooting for Document Feeding Problems
4.11.1 No document is fed
<User Check>
• Set the document properly and check that the display on the LCD changes.
• Check that the number of paper set has not exceeded the upper limit in the document tray.
• Check that the ADF cover is closed correctly.
4.11.2 Multiple documents are fed
<User Check>
• Check that the thickness of the document is 64 to 105 g/m
2
.
• Check that the number of paper set has not exceeded the upper limit in the document tray.
Step
Cause
Remedy
1
Document detection actuator
coming off
Reattach the document detection actuator.
2
Connection failure of the ADF
motor harness
Reconnect the ADF motor harness.
3
Boss to push the ADF cover
sensor of the ADF cover
Replace the ADF cover ASSY.
4
Document separate roller
failure
Replace the document separate roller ASSY.
5
Damaged ADF drive gear
Replace the ADF unit.
6
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Abrasion of ADF separation
pad
Replace the ADF separation pad.
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...