5 - 16
Failure Investigation
for Electronic Parts
Does not operate when the foot controller is used
Does not operate when the foot controller is used.
Replace the foot controller
jack assy.
N
Is the resistance between pin 2 and 3 on the
foot controller jack assy. connector normal?
• Foot controller disconnected : 1
Ω
or less
• Foot controller connected : more than 1M
Ω
Y
Replace the foot controller.
or
Replace the foot controller
jack assy.
N
Y
When the foot controller is connected
and press down the foot controller,
does the resistance between pin 1
and 3 on the foot controller jack assy.
connector 1K-51K
Ω
?
Replace the main PCB assy.
Summary of Contents for CE-8080PRW
Page 1: ......
Page 2: ......
Page 3: ......
Page 17: ...2 2 Main parts Main parts location diagram BasicsofDisassembly ...
Page 27: ...2 12 Feed mechanism Feed mechanism location diagram BasicsofDisassembly ...
Page 29: ...2 14 Bobbin winder mechanism Bobbin winder mechanism location diagram BasicsofDisassembly ...
Page 31: ...2 16 Bobbin winder mechanism Bobbin winder mechanism location diagram BasicsofAssembly ...
Page 33: ...2 18 Feed mechanism Feed mechanism location diagram BasicsofAssembly ...
Page 44: ...2 29 Basics Main parts Main parts location diagram BasicsofAssembly ...
Page 49: ...3 2 Main parts Main parts location diagram ApplicationofDisassembly ...
Page 89: ...3 42 Main parts Main parts location diagram ApplicationofAssembly ...
Page 111: ...3 64 Bobbin winder mechanism Bobbin winder mechanism location diagram ApplicationofAssembly ...
Page 113: ...3 66 Feed and rotary module Feed and rotary module location diagram ApplicationofAssembly ...
Page 127: ...3 80 Needle presser module Needle presser module location diagram ApplicationofAssembly ...
Page 196: ......