4-3
Confidential
1.1.2 Writing firmware
(1) Press and hold the [Stop] and [Scan to PC] buttons simultaneously, and plug the AC
cord into the outlet. Check that the Power LED and the Error LED are lit, and release
these two buttons.
(2) Press the [Scan to PC] button, and then the [Stop] button. The Power LED and the Scan
to PC LED light, and the machine enters firmware writing mode.
(3) Connect the computer to the machine with the USB cable.
(4) Turn ON the power switch of the computer.
(5) Open the temporary folder and double-click "Filedg32.exe" to start it, and select the
"Brother Maintenance USB Printer".
(6) Drag and drop the firmware (LZXXXX_$.upd) in the same folder onto the "Brother
Maintenance USB Printer" icon. The firmware file is loaded to the machine, and writing
to the flash ROM starts.
(7) The LED flashes randomly during writing. When writing is completed, the machine
restarts and returns to the ready state automatically. Do not disconnect the USB cable or
turn OFF the power switch of the computer until writing is completed.
(8) Turn OFF the power switch of the machine, and disconnect the USB cable.
Summary of Contents for ADS-2000e
Page 15: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 22: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 28: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 50: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 54: ...3 2 Confidential 2 PACKING ...
Page 93: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 107: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 113: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 116: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 117: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 119: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 123: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...