2-19
Confidential
Vertical streaks
White vertical streaks
Hue defect
<User Check>
- Clean the CIS glass.
- Clean the document pressure bar.
Step
Cause
Remedy
1
First side or second side CIS unit
failure
Replace the first side or second side CIS
unit.
<User Check>
- Clean the CIS glass.
- Clean the document pressure bar.
Step Cause
Remedy
1
First side or second side CIS unit
failure
Replace the first side or second side CIS
unit.
Step Cause
Remedy
1
Color parameter failure
Execute the maintenance mode function
"Acquire white level data and set CIS scan
area".
2
First side or second side CIS unit
failure
Replace the first side or second side CIS
unit.
3
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for ADS-2000e
Page 15: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 22: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 28: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 50: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 54: ...3 2 Confidential 2 PACKING ...
Page 93: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 107: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 113: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 116: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 117: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 119: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 123: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...