4-6
Confidential
1.5
Acquiring White Level Data
(1) Press and hold the [Stop] and [Scan to USB] buttons simultaneously, and plug the AC
cord into the outlet. The Power LED and the Error LED light.
(2) Press the [Stop], [Scan to USB], [Scan to PC], and [Stop] buttons in this order.
The Scan to PC LED and the Scan to USB LED light.
(3) Press the [Scan to PC] button. The Scan to PC LED and the Scan to USB LED go out,
and the machine enters maintenance mode for service personnel.
(4) Press the [Scan to USB] button six times. The Scan to PC LED and the Power LED light.
(5) Press the [Stop] button. All LEDs go out, and CIS scan area setting starts.
(6) When CIS scan area setting is completed normally, the Scan to PC LED and the Power
LED light. If any error is detected during setting, the Scan to USB LED, the Power LED,
and the Error LED light.
(7) When completed normally, turn off the power of the machine.
1.6
Setting Double Feeding Sensor Threshold
(1) Press and hold the [Stop] and [Scan to USB] buttons simultaneously, and plug the AC
cord into the outlet. Check that the Power LED and the Error LED are lit, and release
these two buttons.
(2) Press the [Stop], [Scan to USB], [Scan to PC], and [Stop] buttons in this order.
The Scan to USB LED and the Scan to PC LED light.
(3) Turn ON the power switch of the computer.
(4) Connect the computer to the machine with the USB cable.
(5) Press and hold the [Stop] button until the Power LED lights.
(6) Double-click "BrADSmt1.exe" that was copied into the temporary folder to start it.
(7) Select the model name in the [Select model:] box, and click the [Start] button.
The double feeding sensor threshold is set.
Note:
• To use remote check mode, the computer needs to be connected to the machine
with the USB cable and the power switch of the computer must be turned ON before
proceeding to step 6.
Summary of Contents for ADS-2000e
Page 15: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 22: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 28: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 50: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 54: ...3 2 Confidential 2 PACKING ...
Page 93: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 107: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 113: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 116: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 117: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 119: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 123: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...