Troubleshooting for Error Display
4.1.1 All scanned data are printed as blank page.
4.1.2 The machine and USB cable were not connected when "to PC" was executed.
4.1.3 There was insufficient memory in the machine when "to PC" was executed.
There was insufficient memory in the machine when "to FTP" was executed.
There was insufficient memory in the machine when "to WS SCAN" was
executed.
4.1.4 There was insufficient space in the connected USB flash memory drive when "to
USB" was executed.
Numbers of files and folders stored in the USB flash memory drive exceeded the
upper limit when "to USB" was executed.
Sequential number of files and folders stored in the USB flash memory drive
exceeded the upper limit when "to USB" was executed.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Check that the USB cable is free from breakage.
• Check that the USB cable is connected to the machine correctly.
• Check that the computer is running.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Reduce the number of documents and scan again.
• Reduce the resolution and scan again.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Delete some data in the USB flash memory drive.
• Change the USB flash memory drive.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.