2-34
Confidential
■
Error code 12
Inter-color position alignment adjustment failure.
(Incorrect measurement value of inter-color position alignment adjustment.)
<User Check>
- Replace the toner cartridge with a new one.
- Replace the belt unit with a new one.
- Replace the waste toner box with a new one.
■
Error code 16
Paper of unsupported size for duplex printing or paper of different sizes is loaded.
<User Check>
- Use the A4 or Letter size paper.
(Non Touch panel model)
Registration
Registration failed. See Troubleshooting chapter in User’s Guide.
(Touch panel model)
Registration failed
Registration failed. See Troubleshooting chapter in User’s Guide.
Step
Cause
Remedy
1
Foreign object is affixed around
the density sensor
Remove the foreign object affixed around
the density sensor.
2
Harness connection failure of
registration mark sensor holder
ASSY
Check the harness connection of the
registration mark sensor holder ASSY and
reconnect it.
3
Registration mark sensor PCB
failure
Replace the registration mark sensor
holder ASSY.
4
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.
5
Engine PCB failure
Replace the engine PCB ASSY.
6
Low-voltage power supply PCB
failure
Replace the low-voltage power supply
PCB ASSY.
7
Main PCB failure
Replace the main PCB ASSY.
Duplex Disabled
Reload paper, then press Start.
Step
Cause
Remedy
1
Registration rear actuator
catching on some position
Correct the position of the registration rear
actuator.
2
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for 09055CDN
Page 22: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 37: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 47: ...2 8 Confidential ADF part A4 model Fig 2 6 Left side Right side Document feed path Face up ...
Page 48: ...2 9 Confidential ADF part Legal model Fig 2 7 Left side Right side Document feed path Face up ...
Page 180: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Page 211: ...3 28 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Page 212: ...3 29 Confidential Disassembly Re Assembly second ...
Page 416: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 436: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 445: ...5 7 Confidential Black and white scanning First side Front Fig 5 1 ...
Page 446: ...5 8 Confidential Black and white scanning Second side Back Fig 5 2 ...
Page 447: ...5 9 Confidential Color scanning First side Front Fig 5 3 ...
Page 448: ...5 10 Confidential Color scanning Second side Back Fig 5 4 ...
Page 475: ...5 37 Confidential Cover page sample Fig 5 18 End page sample Fig 5 19 ...
Page 482: ...5 44 Confidential Inter color position alignment adjustment chart Fig 5 23 ...
Page 491: ...5 53 Confidential Color test pattern Fig 5 28 MCYK Y C K M YCMK_ _A ...
Page 512: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 514: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Page 515: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Page 516: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Page 517: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 518: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 519: ...6 6 Confidential NCU PCB Circuit Diagram U S A Canada ...
Page 520: ...6 7 Confidential NCU PCB Circuit Diagram Europe Oceania ...
Page 521: ...6 8 Confidential NCU PCB Circuit Diagram China Asia South Africa Gulf ...
Page 523: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 581: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 585: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Page 589: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...