Service Procedures
PreciseFlex™ DDR Collaborative Robots
P/N: PFD0-DI-00010, Rev 5.0.0, April 9, 2022
114
Copyright © 2022, Brooks Automation, Inc.
7.
Recalibrate the robot.
Replacing the Z axis Slave Controller
DANGER:
Before replacing any Controller, the AC power should be
removed.
Tools Required:
1.
2.0mm hex driver
2.
2.5mm hex driver
Spare Part Required: G6X0-EA-00202 with thermal pad
To replace the Z axis Slave Controller the user must:
1.
Turn off the robot power and remove the AC power cord.
2.
Remove the curved read cover from the Z column.
3.
Remove the Gripper Controller by removing 4 M3 X 10mm SHCS and unplugging the cables.
4.
Replace the Slave Controller and re-attach the harness.
5.
Set the jumpers correctly for the address and termination.
6.
Replace the curved rear cover.
7.
Recalibrate the robot.