MagnaTran 7.1 User’s Manual
Maintenance and Repair
MN-003-1600-00
Z Encoder Replacement
Brooks Automation
Revision 2.2
9-45
Z Encoder Replacement
NOTE:
It is not necessary to remove the robot to perform this repair procedure.
Required Tools
Performing the Z Board replacement procedure requires the following tools:
•
Medium phillips head screwdriver
•
Small flat head screwdriver
•
M3 hex wrench
•
Small Phillips head screwdriver
•
4-40 (3/32”) hex wrench
•
Loctite, removable strength, #242
Removal Procedure
WARNING
When equipment is off and power is secured per facilities lockout/
tagout procedure, the unit is classified as a Type 1 hazard category.
See
.
1.
Turn off power to the robot and disconnect the power and communications
connections to the robot.
DANGER
All power to the unit must be disconnected per the facilities’ lockout/
tagout procedure before servicing to prevent the risk of electrical
shock.
2.