Command Reference
MagnaTran 7.1 User’s Manual
Reset
MN-003-1600-00
Brooks Automation
8-118
Revision 2.2
Reset
Purpose:
This command is used to perform a software reset of the robots’s firmware.
Format:
RESET
Description:
Performs a software reset of the robot’s firmware that is functionally equivalent to
turning the power off and then back on. All parameters stored in RAM will be
replaced by the values stored in non-volatile memory. After approximately 30 sec-
onds, a “ready” response is returned when reset as complete.
Example:
The following example resets the MagnaTran 7 and loads the user’s default settings
stored in non-volatile memory for all parameters.
RESET