MagnaTran 7.1 User’s Manual
Command Reference
MN-003-1600-00
Mount
Brooks Automation
Revision 2.2
8-51
Mount
Purpose
Causes the robot to move to the “mount new arms” position, which is defined as an R
axis shaft angle of 90°, and a Z position as established by the SET MOUNT Z com-
mand.
Format
MOUNT
Arguments
None
Description
The actual executed sequence is:
•
Home R axis
•
Home T axis
•
Home Z axis
Move (slow speed) along Z to the vertical mount position as established by the SET
MOUNT command. The default setting for SET MOUNT is 10.000 mm above the
Home position.