Operation
3.1
Powering up and powering down
It is recommended to turn on power before applying pressure and to switch off power after removing pressure.
Be sure to apply the specified operating pressure(s) . Avoid pressure shocks and bring the fluidic system gradually up to the
level of operating conditions; open and close the fluid supply gently.
3.2
First use
Before starting measurement and control, make sure to expel gas from the system by flushing all fluidic lines with the
process fluid at a relatively high flow rate.
For controllers, give setpoint = 100% or use special
= 8 (valve fully open), to ensure getting the highest
possible flow rate. Control mode 8 bypasses the PID controller, which is particularly useful when having the ES-FLOW™ set
to a low capacity flow range.
3.3
User interface
The screen representations in this section are for illustration purposes only. They do not necessarily reflect the exact lay-out
and/or information displayed on the screen. Some representations might only be applicable to certain instrument types or
factory configurations.
The image to the right shows the screen display, immediately after powering up. The following screen areas can be
distinguished:
1. Top line
2. Measure readout
3. Custom readout 1 (only for instruments with control
function)
4. Custom readout 2
The navigational buttons have the following functionality:
·
Enter selected menu
·
Enter edit mode
·
Confirm selection/changes
·
Navigate up in menu
·
Change character or list item
·
Navigate down in menu
·
Change character or list item
·
Return to previous menu
·
Leave edit mode without making changes
·
Select display info