23
VFD Setup
1.
Install cord grips and wire 4 conductor cable (coming from motor). Strip 4-
6” of cable
jacket and separate each wire. Strip and install supplied ferrules and y
connector(ground). Install according to the diagram
as shown in “A” below.
If the
motor runs backwards, switch the red and white wires.
a.
GREEN
–
GROUND SCREW
b.
BLACK
–
U
c.
WHITE
–
V
d.
RED
–
W
a.
Install cord grips and wire 3 conductor cable (coming from motor). Strip 4-
6” of
cable jacket and separate each wire. Strip and install supplied ferrules and y
connector(ground). Install according to the diagram
as shown in “
B
” below.
Turn cord grips until tight after connections are done.
b.
GREEN
–
GROUND SCREW
c.
BLACK
–
L1
d.
WHITE
–
L2
2.
Set the input voltage jumper (J1) to the correct supply voltage (230V shown in
photo). Standard Household voltage is 115
3.
Close VFD. Install plug or directly wire into supply power junction box.