FIGURE 14 Device installed in the rack
1.
Screw locations
4. Secure the device to the equipment rack racks with six 10-32 x .63 screws, three screws on each side. See the previous figure.
5. Tighten the screws to a torque of 29.2 to 36.5 in-lb (33.6 to 42 cm-kg).
Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation
(XBR-RMK-FL-4DS-2 and XBR-RMK-RE-4DS-2)
Use the following instructions to install a Intake Air Duct Kit in a 19 in. (48.26 cm) Electronic Industries Association (EIA) rack in either a
flush or recessed configuration using one of the following Brocade Intake Air Duct Kits:
∙
XBR-RMK-FL-4DS-2 - Flush mount kit for rack rail-to-rail depth of 27 to 31 in. (68.58 to 78.74 cm).
∙
XBR-RMK-RE-4DS-2 - Recessed kit for rail-to-rail depth of 27 to 31 in. (68.58 to 78.74 cm)
Mounting the Device
Brocade VDX 8770-4 Hardware Installation Guide
53-1002563-10
39