18
Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Product Name configuration
2
Synchronizing local time using NTP
Perform the following steps to synchronize the local time using NTP.
1. Log into the switch using the default password, which is password.
2. Enter the tsClockServer command:
switch:admin> tsclockserver
"
<ntp1;ntp2>"
where
ntp1
is the IP address or DNS name of the first NTP server, which the switch must be
able to access. The second
ntp2
is the second NTP server and is optional. The operand
“<ntp1;ntp2>” is optional; by default, this value is LOCL, which uses the local clock of the
principal or primary switch as the clock server.
switch:admin>
tsclockserver
LOCL
switch:admin>
tsclockserver "132.163.135.131"
switch:admin>
tsclockserver
132.163.135.131
switch:admin>
The following example shows how to set up more than one NTP server using a DNS name:
switch:admin>
tsclockserver
"10.32.170.1;10.32.170.2;ntp.localdomain.net"
Updating Clock Server configuration...done.
Updated with the NTP servers
Changes to the clock server value on the principal or primary FCS switch are
propagated to all switches in the fabric