84
Brocade FastIron GS and FastIron GS-STK Hardware Installation Guide
53-1001783-01
Managing temperature settings
7
DRAFT: BROCADE CONFIDENTIAL
The following output is for an IronStack:
Displaying temperature messages
The software sends a Syslog message and an SNMP trap if the temperature crosses the warning
threshold. The following methods describe how to view the system log on the device. If you have
configured the device to use a Syslog server or SNMP trap receiver, refer to the documentation for
the server or receiver.
To display the system log, enter the following command at any CLI level. The following example is for
a standalone device. To display system logs for IronStack devices, enter the show log command for
individual stack units.
FastIron> show chassis
power supply 1 <NA - AC - Regular> present, status ok
power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 28.5 degrees Celsius
Warning level.......: 45.0 degrees Celsius
Shutdown level......: 55.0 degrees Celsius
Intake Side Temperature Readings:
Current temperature : 29.0 degrees Celsius
Boot Prom MAC: 00e0.5200.0100
FGS648P Switch# show chassis
The stack unit 1 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 35.5 deg-C
Warning level.......: 80.0 deg-C
Shutdown level......: 90.0 deg-C
Intake Side Temperature Readings:
Current temperature : 33.5 deg-C
Boot Prom MAC: 0012.f2de.9440
Management MAC: 0000.0000.0011
The stack unit 2 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
--More--, next page: Space, next line: Return key, quit: Control-c