Chassis slots
Chassis slots are numbered 1 through 12, from left to right when facing the port side of the Brocade DCX. Control processor blades
(CP8) can be installed only in slots 6 and 7. Core switch blades (CR8) can be installed only in slots 5 and 8. The rest of the slots ,1-4 and
9-12, can be filled with port, application, or encryption blades. Unused slots must be filled with blade filler panels to maintain adequate
cooling.
Port numbering
The Brocade DCX uses the following port numbering method (
on page 149).
Port or application blade
Port numbering
Trunking port group numbering
FC8-16 port blade
•
0 through 15 from bottom to top.
FC8-32 port blade
•
0 through 15 from bottom to top on the left set of
ports.
•
16 through 31 from bottom to top on the right set
of ports.
FC8-48 port blade
•
0 through 23 from bottom to top on the left set of
ports.
•
24 through 47 from bottom to top on the right set
of ports.
FC8-64 port blade
•
0 through 31 from bottom to top on the left set of
ports.
•
32 through 63 from bottom to top on the right set
of ports.
•
0-7, 8-15, 16-23, 24-31, 32-39, 40-47,
48-55, and 56-63.
FS8-18 blade
•
FC ports: 0 through 15 from bottom to top.
•
10/100/1000 BaseT ports: GE0 and GE1 from
the bottom.
FX8-24 blade
•
FC ports: 0 through 11 in two vertical rows of six
ports starting from the bottom left and bottom right
in the lower group of 12 ports. Labeled as FC on
the front panel diagram.
•
10-GbE ports: 0 and 1 in the left-hand column just
above the FC ports. Labeled as 10GE on the front
panel diagram.
•
1-GbE ports: 0 through 9 in both columns above
the FC and 10GE ports. Labeled as GE on the
front panel diagram.
Up to three FC trunking groups are permitted.
•
Trunk group 0: FC ports 0, 1
•
Trunk group 1: FC ports 6, 7
•
Trunk group 2: FC ports 2, 3, 4, 5, 8, 9, 10,
11
FCOE10-24 blade
•
0 through 23 in two vertical rows from bottom left
to top right.
High availability
The following features contribute to the Brocade DCX high-availability design:
•
Redundant, hot-swappable blades and FRUs
•
Enhanced data integrity on all data paths
•
Fabric Shortest Path First (FSPF) rerouting around failed links
Chassis slots
Brocade DCX Backbone Hardware Installation Guide
20
53-1000685-24
Summary of Contents for DCX Backbone
Page 8: ...Brocade DCX Backbone Hardware Installation Guide 8 53 1000685 24...
Page 12: ...Brocade DCX Backbone Hardware Installation Guide 12 53 1000685 24...
Page 14: ...Brocade DCX Backbone Hardware Installation Guide 14 53 1000685 24...
Page 24: ...Brocade DCX Backbone Hardware Installation Guide 24 53 1000685 24...
Page 28: ...Brocade DCX Backbone Hardware Installation Guide 28 53 1000685 24...
Page 46: ...Brocade DCX Backbone Hardware Installation Guide 46 53 1000685 24...
Page 50: ...Brocade DCX Backbone Hardware Installation Guide 50 53 1000685 24...
Page 82: ...Brocade DCX Backbone Hardware Installation Guide 82 53 1000685 24...
Page 138: ...Brocade DCX Backbone Hardware Installation Guide 138 53 1000685 24...
Page 142: ...Brocade DCX Backbone Hardware Installation Guide 142 53 1000685 24...
Page 148: ...Brocade DCX Backbone Hardware Installation Guide 148 53 1000685 24...