If you have one or more application blades in the chassis, the Fabric OS automatically detects
mismatches between the active CP firmware and the application blade's firmware and triggers the
auto-leveling process. This auto-leveling process automatically updates the application blade
firmware to match the active CP. At the end of the auto-leveling process, the active CP and the
application blades will run the same version of the firmware.
Core switch blade (CR16-8) removal and replacement
This section describes how to remove and replace a core switch blade (CR16-8). The Brocade DCX
8510-8 has two core switch blades: one in slot 5 and one in slot 8.
Time and items required
The replacement procedure for the core switch blade takes approximately 30 minutes. The following
items are required for the core switch blade replacement:
• Electrostatic discharge (ESD) grounding strap
• #2 Phillips screwdriver
• Replacement core switch blade
Faulty core switch blade indicators
Confirm that you need to replace the core switch blade before continuing. The following events may
indicate that a core switch blade is faulty:
• The status LED on the core switch blade is lit steady amber, or the power LED is not lit.
• The
slotShow
command does not show that the core switch blade is enabled.
• The
haShow
command indicates an error.
• Any of the following messages display in the error log:
‐
"Slot unknown" message relating to a core switch slot
‐
Core switch blade errors or I2C timeouts
‐
FRU: FRU_FAULTY messages for a core switch blade
‐
Configuration loader messages or "Sys PCI config" messages
‐
Generic system driver messages ("FABSYS")
‐
Platform system driver messages ("Platform")
‐
EM messages that indicate a problem with a core switch blade
‐
Function fail messages for the core switch master
For more information about error messages, refer to the
Fabric OS Message Reference
.
Removing a core switch blade (CR16-8)
Follow electrostatic discharge (ESD) precautions when removing a blade. Wear a wrist grounding
strap connected to chassis ground (if the Brocade DCX 8510-8 is plugged in) or a bench ground.
DANGER
For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.
Core switch blade (CR16-8) removal and replacement
92
Brocade DCX 8510-8 Backbone Hardware Reference Manual
53-1002180-08
Summary of Contents for DCX 8510-8
Page 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Page 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...