Limitations of FCOE10-24 blade
The following limitations have to be considered when using FCOE10-24 application blade with Fabric
OS 7.3.0, on the DCX 8510-8 chassis:
• FCOE10-24 blade is supported only in slot 1 of the 8510-8 chassis.
• Supports maximum of one FCOE10-24 blade per 8510-8 chassis.
• FCOE10-24 blade can be installed concurrently with FC16-32 and FC8-32E blades only.
• FCOE10-24 blade cannot be used in the DCX 8510-8 chassis with FC16-48, FC16-48E, FC8-64 or
FC16-64 blades.
• FCOE10-24 blade cannot be used in a DCX 8510-8 chassis with other intelligent or application
blades.
• Support is limited to FCoE direct attach only.
• Upgrade and downgrade considerations are same as DCX.
NOTE
For complete list of limitations on the FCOE10-24 blade, refer to the Fabric OS Release Notes.