- 6 -
DEPTH ADJUSTMENT
SCREWS
INSTALL THE HOOD
1. Hang the hood from the brackets through
the
rectangular cut-outs
on the back of
the hood. Cut-outs are larger than the
brackets to allow for horizontal adjustment.
The bottom of the hood should be 24" to
30" above the cooking surface.
2.
Height adjustment screws
provide vertical
adjustment.
3.
Depth adjustment screws
provide hori-
zontal adjustment.
4. Secure the hood with
mounting screws
(4,8x38mm). Use drywall anchors,
provided, if wall studs or framing are not
available.
5. Remove the tape located on the damper.
MOUNTING
SCREWS
(4,8x38mm)
MOUNTING
BRACKETS
HEIGHT ADJUSTMENT
SCREWS
WALL FRAMING
MOUNTING
SCREWS
(4,8x38mm)
RECTANGULAR
CUTOUTS
MOUNTING SCREWS
(4,8x38mm)
REMOVE THE TAPE
HOOD DISTANCE ABOVE 36” HIGH COOK TOP
8’ Ceiling
Standard Flues
9’ Ceiling
10’ Ceiling
Minus 24 - 29
¼
25 - plus
30”
-