TYPICAL INSTALLATIONS

Housing mounted to I-joists.

 

Use I-joist spacer block (provided).

Housing mounted to joists.

Housing mounted to truss.

PLAN THE INSTALLATION

ROOF CAP 

*

6-IN. OR 4-IN. 

ROUND

ELBOW 

*

6-IN. OR 4-IN. 

ROUND

DUCT 

*

WALL

CAP 

*

*

 Purchase

separately

The unit will operate most quietly and efficiently when located 

where the shortest possible duct run and minimum number of 

elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce 

backdrafts.
Plan to supply the unit with proper line voltage and appropriate 

power cable.

Summary of Contents for QTR140

Page 1: ... ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this three year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warr...

Page 2: ...F CAP 6 in or 4 in ROUND ELBOW 6 in or 4 in ROUND DUCT WALL CAP Purchase separately The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Use a roof cap or wall cap that has a built in damper to reduce backdrafts Plan to supply the unit with proper line voltage and appropriate power cable ...

Page 3: ...rk Connect 6 inch or 4 inch round duc twork to damper duct connector Run ductwork to a roof cap or wall cap Tape all ductwork connections to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contact the bottom of the joist The housing mounts with four 4 screws ...

Page 4: ...2 req d 14 99111293 Spacer 2 supplied 15 475 Duct Reducer 6 to 4 16 99420665 Thumbscrew 8 18 x 375 INSTALL GRILLE 7 Attach grille to housing Squeeze grille springs and insert them into slots on each side of hous ing 8 Push grille against ceil ing 6 Finish ceiling Install ceiling material Cut out around housing SERVICE NOTE To remove Blower Assem bly Unplug motor 7 Remove thumbscrew 16 from motor p...

Page 5: ... tos estarán libres de defectos en cuanto a material y mano de obra durante un período de tres años a partir de la fecha de la compra original NO EXISTEN OTRAS GARANTÍAS EXPRESAS NI IMPLÍCITAS INCLUIDAS PERO SIN LIMITARSE A GARANTÍAS IMPLÍCITAS DE COMERCIAL IZACIÓN O IDONEIDAD PARA UN PROPÓSITO PARTICULAR Durante este período de tres años Broan NuTone a su criterio reparará o reemplazará sin cargo...

Page 6: ...O REDON DO DE 6 o 4 PULG CONDUCTO REDONDO DE 6 o 4 PULG TAPA DE PARED Se compran por separado El ventilador funcionará con más eficiencia y menos ruido si se ubica en un sitio donde requiera el tramo de conducto más corto posible y un mínimo número de codos Instale una tapa de techo o de pared que tenga un regulador de tiro incorporado a fin de reducir los contratiros Alimente la unidad con el vol...

Page 7: ...le reductor de conducto de 6 á 4 pulg sobre conector de conducto 4 Instale el conducto redondo de 6 o 4 pulga das Conecte el conduc to redondo de 6 o 4 pulgadas al conec tor del regulador conducto Extienda el conducto hacia una tapa de techo o tapa de pared Encinte todas las conexiones de los conductos para fijarlas y hacerlas herméticas al aire 2 Monte la cubierta en la vigueta Sostenga la cubi e...

Page 8: ...665 Tornillo de mariposa n o 8 18 x 0 375 INSTALE LA REJILLA 7 Acople la rejilla a la cubierta Apriete los resortes de la rejilla e insér telos en las ranuras que se encuentran a cada lado de la cubierta 8 Empuje la rejilla contra el cielo raso 6 Termine el cielo raso Instale el material del cielo raso Recorte alrededor de la cubierta NOTA DE SERVICIO Para desmontar el conjunto del ventilador Dese...