WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 

TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. If 

you have questions, contact the manufacturer at the address or

telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service panel 

and lock the service disconnecting means to prevent power from

being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards,

including fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to pre-

vent backdrafting. Follow the heating equipment manufacturer’s 

guideline and safety standards such as those published by the

National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers 

(ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage elec-

trical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  To reduce the risk of fire, use only metal ductwork.
8.  Models L100, L150, L200, L250, and L300 only:

If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI

(Ground Fault Interrupter) - protected branch circuit.

9.  Never place a switch where it can be reached from a tub or shower.
10. This unit must be grounded.

CAUTION

1.  For general ventilating use only. Do not use to exhaust hazardous 

or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power

unit.

3.  Please read specification label on product for further information

and requirements.

READ AND SAVE THESE INSTRUCTIONS

LOSONE SELECT

®

 VENTILATORS

Ceiling/Wall Mount

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

TYPICAL INSTALLATION

MOUNTING 

(New Frame Construction)

Factory-shipped unit installed in new construction.

CEILING JOIST

(16” centers shown)

ROUND DUCT*

GRILLE

(Polymeric

shown)

Install after

ceiling is

finished.

MOUNTING

SCREW

GRILLE

SCREW

Blower factory-shipped

in horizontal

discharge position.

Mounting brackets 

factory-shipped in 

position for ½” ceil-

ing material.

ADDITIONAL

1½” FRAMING

MOUNTING 

(Existing Frame Construction)

Factory-shipped unit installed in existing construction.

ROUND DUCT*

GRILLE

SCREW

FINISHED

CEILING

MATERIAL

GRILLE

(Polymeric shown)

CEILING JOIST

(16” centers

shown)

2 X 4 FRAMING

(wide side down)

MOUNTING

BRACKETS

(Attached to

opposite sides

of housing & up-

side-down,

so housing is

flush with

finished ceiling)

* L100 & L150 Series uses 6” Round Duct.

L200, L250, & L300 Series uses 8” Round Duct.

1

BROAN LIGHT DUTY SERIES- EXHAUST FAN 

INSTALLATION GUIDE

Summary of Contents for LOSONE SELECT L2000L

Page 1: ...d L300 only If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Nev...

Page 2: ...CKNESSES Mounting brackets flipped over to give approx 1 more clearance Outlet parallel to joists New construction Mounting brackets mounted to top of sides of housing Outlet parallel to joists New or...

Page 3: ...esta unidad solamente de la manera indicada por el fabricante Si tiene preguntas p ngase en contacto con el fabricante a la direcci n o tel fono que aparecen en la garant a 2 Antes de limpiar o de po...

Page 4: ...ISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE T...

Page 5: ...OUND TO WIRING PLATE 10 ROUND DUCT GRILLE SCREW FINSHED CEILING MATERIAL GRILLE CEILING JOIST 24 centers shown 2 X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing up s...

Page 6: ...ge position Factory shipped DUCT CONNECTOR Blower and duct connec tor in vertical discharge position BLOWER BLOWER Change blower duct connector positions for vertical discharge DUCTING Vertical blower...

Page 7: ...L400C 99080499 Motor L500C 99080500 Motor L700C 99080508 Motor L400EX 99080509 Motor L500EX 99080510 Motor L700EX 19 97014794 Motor Mounting Bracket 20 99100497 Rubber Isolator 4 req 21 99160380 Screw...

Page 8: ...S IMPLIED BY LAW INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE To the extent that applicable law prohibits the exclusion of implied warranties the duration...

Page 9: ...ctwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes ROOF CAP 12 ROUND ELBOW 12 ROUND DUCT WALL CAP IMPORTANT Remove ship...

Page 10: ...ng To clean grille Use appropriate vacuum attachment or remove grille and clean with a soft cloth and mild soap or detergent Dry grille thoroughly before reinstalling To clean blower assembly Remove g...

Page 11: ...Motor Bracket 20 99260477 Whiz Nut 20 11 req 21 99200202 Screw 20 x 5 req 22 97014785 Blower Scroll 23 99080490 Motor L900 99080491 Motor L1500 99080501 Motor L900C 99080502 Motor L1500C 99080511 Mot...

Page 12: ...Heating Refrigeration andAir Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 D...

Page 13: ...ousing 3 8 MIN THREADED RODS By Others DIM L2000L L3500EXL A 7 3 4 10 1 4 B 33 3 4 41 3 4 Mounting with threaded rods through adjustable mounting brackets located at bottom of housing Mounting bracket...

Page 14: ...G OPTIONS EXHAUST ACCESS PANEL INTAKE SLEEPER 1 1 4 Typical wall mounting with 3 8 threaded fasteners by others through mounting brackets Connect electrical power cable to housing with proper connecto...

Page 15: ...purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR...

Reviews: