11. INSTALL THE DEVIATOR (INTERIOR BLOWER)
Install the deviator as shown.
NOTE: To prevent the deviator from sliding out of the rough-in
plate, put some tape on the deviator base after sliding it
into the rough-in plate (provided with the P5 and P8 blower)
opening. If installed correctly, the deviator will protrude
about 1/8” above the rough-in plate.
12. INSTALL THE ADAPTER (INTERIOR BLOWER)
Using two (2) #6 x 1/2’’ screws provided with insert, secure the adapter to the top of the rough-in plate.
Remove tape from damper flap. Seal the adapter to the rough-in plate by using duct tape.
10. REMOVE THE KNOCK-OUT OPENING (INTERIOR BLOWER)
Remove the knockout on rough-in plate. See picture below.
CAUTION
When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove
the knockout corresponding to the ducting installed (10’’ or 14’’ adapter/damper).
Removing vertical knockout opening on rough-in plate
HD0077
14’’
KNOCK
OUT
10’’
KNOCK
OUT
::
rangehoods
.