Page 1: ...INTENDED FOR DOMESTIC COOKING ONLY INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 13 AND 14 SV08341 rev A HB0072 INSTALLATION INSTRUCTIONS READ AND SAVE THESE...

Page 2: ...REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAR...

Page 3: ...CAP MODEL 643 8 ROUND WALL CAP 8 ROUND STANDARD DUCT MODEL 407 7 ROUND 2 FT SECTIONS MODEL 413 TRANSITION 3 X 10 TO 8 SINGLE BLOWER 600 CFM RECIRCULATION KIT ANKE60 SERIES MODEL 415 7 ROUND ADJUSTABL...

Page 4: ...DES ONE 8 TO 10 ROUND TRANSITION MODEL 331H 600 CFM OR 332H 900 CFM EXTERIOR BLOWER MODEL 335 1200 CFM OR 336 1500 CFM EXTERIOR BLOWER MODEL 441 10 ROUND WALL CAP MODEL 437 HIGH CAPACITY ROOF CAP MODE...

Page 5: ...of 30 above cooktop is highly recommended for best capture of cooking impurities Distances over 30 are at the installer and users discretion Hood 3 x 10 duct or 7 or 8 round duct Roof cap Wall cap HH0...

Page 6: ...V 50 W GU 10 2 required for 30 and 36 hood width 3 required for 42 and 48 hood width RMP Series Backsplash optional ANKE60 Series Recirculation kit mandatory for non ducted installation models with bu...

Page 7: ...BOTTOM VIEW 5 5 3 A INTERNAL SINGLE BLOWER HOOD L C INTERNAL SINGLE BLOWER HOOD 2 B 3 5 5 A L C 22 48 INTERNAL DOUBLE BLOWER HOOD 5 10 10 7 8 5 3 4 L C CABINET BOTTOM VIEW 578 HOOD WITH IN LINE OR EXT...

Page 8: ...BLOWER HOODS ONLY Remove both screws retaining the adapter damper 1 from inner top of the hood First unplug both blower motors 1 before removing 3 screws retaining the adapter 2 from inner top of the...

Page 9: ...out the back electrical knock out B HR0024 B A 7 HORIZONTAL DISCHARGE INSTALLATION INTERNAL BLOWER S ONLY All internal blower hoods are factory shipped with the blowers mounted for a vertical dischar...

Page 10: ...ws for a 3 x 10 adapter damper and 4 screws for a 4 x 18 adapter Seal the adapter to the hood using duct tape For round ducting install an appropriate sized transition and seal the joints with duct ta...

Page 11: ...tions included with exterior or in line blower Place the hood under the cabinet and slide it in position Secure the hood by tightening the screws completely Install the last 1 2 double thread screws i...

Page 12: ...clockwise to disengage bulb leads from their grooves NOTE If need be use a rubber dishwashing glove to add grip when removing the bulb 1 2 HO0090 14 REINSTALL GREASE DRIP RAIL AND FILTERS Reinstall gr...

Page 13: ...uch as acetone alcohol ether benzol etc are highly explosive and should never be used close to a range Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish det...

Page 14: ...mal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone LLC faulty installation or instal...

Page 15: ...ONLY WITH APPROPRIATE MAKE UP AIR SYSTEM BLU BLU BLU BLU LAMP LAMP ORA COLOR CODE HE0090A BLK BLACK BLU BLUE BRN BROWN ORA ORANGE RED RED WHT WHITE YEL YELLOW WHT WHT SPEED CONTROL HS THERMOSTAT BLU...

Page 16: ...5 SV08093 PILOT LAMP ASS Y 1 1 1 1 SV08341 INSTALLATION GUIDE 1 1 1 1 PARTS BAG 2 WIRE CONNECTORS 9 SCREWS NO 8 X 1 2 SV08353 1 WIRE CLAMP 8 MECHANICAL 1 1 1 1 SCREWS NO 8 32 X 1 4 4 SCREWS NO 8 X 3 8...