background image

MODEL EIT1366SS

Page 1

READ AND SAVE THESE INSTRUCTIONS

ISLAND
RANGE HOOD

!

 

INTENDED

 

FOR

 

DOMESTIC

 

COOKING

 

ONLY

!

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSON(S) OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

 If you have questions, contact the manufacturer at the 
 address or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

 panel and lock service disconnecting means to prevent 
 power from being switch on accidentally. When the service 
 disconnecting means cannot be locked, securely fasten a 
 prominent warning device, such as a tag, to the service 
panel.

3. Installation work and electrical wiring must be done by 

qualified personnel in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.

4.  Sufficient air is needed for proper combustion and exhausting 

 of gases through the flue (chimney) of fuel burning equipment 
 to prevent backdrafting. Follow the heating equipment 
 manufacturer’s guidelines and safety standards such as 
 those published by the National Fire Protection Association 
 (NFPA), the American Society for Heating, Refrigeration 
 and Air Conditioning Engineers (ASHRAE) and the local 
 code authorities.

5. This product may have sharp edges. Be carefule to avoid 

cuts and abrasions during installation or cleaning.

6. When cutting or drilling into wall or ceiling, do not damage 

 electrical wiring and other hidden utilities.

7. Ducted fans must always be vented to the outdoors.

8. Do not use this unit with any other solid-state speed control 

device.

9. Use only metal ductwork.

10. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a) Never leave surface units unattended at high settings. 

 Boilovers cause smoking and greasy spillovers that may 
 ignite. Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when

 cooking flaming foods (i.e. Crêpes Suzette, Cherries Jubilee,
 Peppercorn Beef Flambé).

c) Clean ventilating fans frequently. Grease should not be 

 allowed to accumulate on fan or filters.

d) Use proper pan size. Always use cookware appropriate for 

 the size of the surface element.

WARNING 

 

TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE 
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE 
FOLLOWING*:

1.  SMOTHER FLAMES with a close-fitting lid, cookie sheet, or 
 

metal tray, then turn off the burner. BE CAREFUL TO PREVENT 

 

BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, 

 

EVACUATE AND CALL THE FIRE DEPARTMENT.

2.  NEVER PICK UP A FLAMING PAN – You may be burned.
3.  DO NOT USE WATER, including wet dishcloths or towels – 
 

This could cause a violent steam explosion.

4.  Use an extinguisher ONLY if:
    A.  You know you have a Class ABC extinguisher and you 
     

know how to operate it.

    B.  The fire is small and contained in the area where it  

 

  

  started.

    C.  The fire department has been called.
    D.  You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION 

!

1. For 

indoor 

use 

only.

2.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

3.  To avoid motor bearing damage and noisy and/or 

unbalanced impeller, keep drywall spray, construction dust,
etc. off power unit.

4.  Do not use over cooking equipment greater than 60,000 

BTU/hr. as the blower motor will shut down intermittently.

5.  Your hood motor has a thermal overload which will 

automatically shut off the motor if it becomes overheated.
The motor will restart when it cools down. If the motor
continues to shut off and restart, have the hood serviced.

6.  The bottom of the hood MUST NOT BE LESS than 26” and 

at a maximum of

 

36” above cooktop for best capture of 

cooking impurities.

7.  Two installers are recommended because of the size of

this hood.

8.  To reduce risk of fire and to properly exhaust air, be sure 

to duct air outside. Do not exhaust air into spaces within
walls or ceilings or into attics, crawl spaces, or garages.

9.  Be careful when installing the decorative flue and hood, 

they may have sharp edges.

10. Please read specification label on product for further 

information and requirements.

INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER.

HOMEOWNER: OPERATION AND MAINTENANCE INFORMATION ON PAGE 2.

WARNING 

 

To register this product visit: 

www.broan-nutone.com or

www.broan-nutone.ca

Summary of Contents for EIT1366SS

Page 1: ...Grease should not be allowed to accumulate on fan or filters d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S...

Page 2: ...less steel surface Avoid When choosing a detergent Any cleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapid...

Page 3: ...On 8 ft ceilings Hood distance above cooktop is Minimum 26 Maximum 34 for ducted discharge Minimum 26 Maximum 30 for non ducted discharge On 9 ft ceilings Hood distance above cooktop is Minimum 26 Ma...

Page 4: ...ROUND DUCTWORK 1 Assemble 4 angle brackets to the lower hood mounting locations using 8 M4 x 10mm pan head machine screws 2 for each angle bracket 2 D e t e r m i n e dimension H based upon ceiling he...

Page 5: ...ling duct and seal with duct tape INNER FLUE OUTER FLUE METAL DUCT METAL DUCT DUCT TAPE BLOWER EXHAUST OPENING POWER CABLE LOUVERS INSTALL THE HOOD Ducted Installation only cont d FRONT 8 M4 x 10mm PA...

Page 6: ...ation above cooktop 7 FT 8 IN CEILING Hood 26 above cooktop H 30 8 FT CEILING Hood 26 above cooktop H 34 Hood 30 above cooktop H 30 9 FT CEILING Hood 26 above cooktop H 46 Hood 30 above cooktop H 42 H...

Page 7: ...D Non Ducted Installation Only cont d FRONT 8 M4 x 10 mm PAN HEAD MACHINE SCREWS 12 Connect power cable to house wiring inside of electrical outlet box Connect the neutral conductor of product WHITE t...

Page 8: ...ntilation ULC recommend to contact a certified service depot for all replacement parts and repairs C D E F G H I J K L M B KEY PART NO DESCRIPTION QTY 1 S99528364 Ceiling Mounting Plate W Outlet Box 1...

Page 9: ...t charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the...

Page 10: ...ltres d Utilisez des casseroles de dimension appropri e Utilisez toujours une batterie de cuisine adapt e la dimension de la surface chauffante AVERTISSEMENT OBSERVEZ LES CONSIGNES SUIVANTES AFIN DE R...

Page 11: ...on couvrir la hotte pour emp cher la poussi re de toucher aux surfaces d acier inoxydable viter Lors du choix d un d tergent Tout nettoyant contenant des agents de blanchiment attaquera l acier inoxyd...

Page 12: ...nimum 26 po maximum 34 po pour une sortie avec conduits Minimum 26 po maximum 30 po pour une sortie sans conduits Pour les plafonds de 9 pi La distance de la hotte au dessus de la surface de cuisson e...

Page 13: ...pour chaque querre 2 D t e r m i n e r la dimension H d apr s la hauteur du plafond et celle de l emplacement de la hotte au dessus du plan de cuisson PLAFOND DE 7 PI 8 PO Hotte 26 po au dessus de la...

Page 14: ...it en m tal celui du plafond et sceller les joints avec du ruban conduit CONDUIT D CORATIF INT RIEUR CONDUIT D CORATIF EXT RIEUR CONDUIT M TALLIQUE CONDUIT M TALLIQUE RUBAN POUR CONDUIT OUVERTURE D VA...

Page 15: ...E 8 PI Hotte 26 po au dessus de la surface de cuisson H 34 po Hotte 30 po au dessus de la surface de cuisson H 30 po PLAFOND DE 9 PI Hotte 26 po au dessus de la surface de cuisson H 46 po Hotte 30 po...

Page 16: ...E D ALIMENTATION PLENUM OUVERTURE D VACUATION DU VENTILATEUR INSTALLATION DE LA HOTTE Inst sans conduit seulement suite FRONT 8 VIS M CANIQUES T TE CYLINDRIQUE M4 x 10 mm 12 Connecter le c ble d alime...

Page 17: ...ue par Broan NuTone LLC ou Venmar Ventilation ULC pour vos pi ces de remplacement et appels de service Inclus avec l option Ensemble de recirculation Mod le ANKIBF4 Veuillez commander les pi ces par n...

Page 18: ...a Soci t vous l indiquera vous devrez l emballer correctement La Soci t n est pas responsable des dommages subis lors du transport La Soci t se r serve le droit d utiliser des produits ou des pi ces r...

Page 19: ...on pimienta flameado c Limpie frecuentemente los ventiladores No permita la acumulaci n de grasa en el ventilador ni en los filtros d Use una cacerola del tama o adecuado Siempre use utensilios de coc...

Page 20: ...para estar seguro de que el polvo no se pegue a la superficie de acero inoxidable Evite Al elegir un detergente Todo limpiador que contenga blanqueador pues atacar al acero inoxidable Todo producto q...

Page 21: ...a de 30 pulg para la descarga de sistemas sin conductos En los cielos rasos de 9 pies La distancia de la campana arriba de la estufa es M nima de 26 pulg m xima de 36 pulg para ambas la descarga de si...

Page 22: ...aje de la campana usando 8 t o r n i l l o s m a q u i n a d o s M4 x 10 mm de cabeza t r o n c o c n i c a 2 para cada soporte en ngulo 2 Determine la dimensi n H con base en la altura del cielo raso...

Page 23: ...nductos TUBOS DE HUMOS INTERIOR TUBOS DE HUMOS EXTERIOR CONDUCTO DE METAL CONDUCTO DE METAL CINTA PARA CONDUCTOS ABERTURA DE DESCARGA DEL VENTILADOR CABLE EL CTRICO ALISTONADOS INSTALE LA CAMPANA s lo...

Page 24: ...8 PULGADAS Campana 26 pulg arriba de la estufa H 30 pulg CIELO RASO DE 8 PIES Campana 26 pulg arriba de la estufa H 34 pulg Campana 30 pulg arriba de la estufa H 30 pulg CIELO RASO DE 9 PIES Campana...

Page 25: ...SCARGA DEL VENTILADOR INSTALE LA CAMPANA s lo en inst sin conductos cont FRONT 8 TORNILLOS MAQUINADOS M4 x 10 mm DE CABEZA TRONCOC NICA 12 Conecte el cable el ctrico al cableado de la casa Conectar el...

Page 26: ...incluye con el conjunto de recirculaci n Modelo ANKIBF4 Otras piezas de servicio indicar por n mero de la pieza no por n mero de clave C D E F G H I J K L M B CLAVE N DE PIEZA DESCRIPCI N CANT 1 S995...

Page 27: ...Producto o la pieza a la Compa a tal como lo indique la Compa a debe empaquetar adecuadamente el Producto o la pieza la Compa a no se hace responsable por los da os en tr nsito La Compa a se reserva...