background image

INST
ALLA
TION MANUAL

SAFETY

3

READ AND SAVE THESE INSTRUCTIONS

!

 Intended for domestic cooking only 

!

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.

In U.S.A., register your range hood online at www.broan.com

In Canada, register your range hood online at www.broan.ca

!

 WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 
PERSONS, OBSERVE THE FOLLOWING:

•  Use this unit only in the manner intended by the manufacturer. If you have 

questions, contact the manufacturer at the address or telephone number 
listed in the warranty.

•  Before servicing or cleaning unit, switch power off at service panel and 

lock the service disconnecting means to prevent power from being 
switched on accidentally. When the service disconnecting means cannot 
be locked, securely fasten a prominent warning device, such as a tag, to 
the service panel.

•  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, including 
fire-rated construction.

•  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 
backdrafting. Follow the heating equipment manufacturer’s guidelines and 
safety standards such as those published by the National Fire Protection 
Association (NFPA) and the American Society for Heating, Refrigeration 
and Air Conditioning Engineers (ASHRAE) and the local code authorities.

•  When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

•  Ducted fans must always be vented to the outdoors.

•  Do not use this unit with any additional solid-state speed control device.

•  To reduce the risk of fire, use only metal ductwork.

•  This unit must be grounded.

•  As an alternative, this product may be installed with the UL-approved cord 

kit designated for the product, following instructions packed with the cord 
kit.

•  When applicable local regulations comprise more restrictive installation 

and/or certification requirements, the aforementioned requirements prevail 
on those of this document and the installer agrees to conform to these at 
his own expense.

Summary of Contents for CLDA1 Series

Page 1: ...WWW BROAN COM Serial number 99045653 003E WWW BROAN CA RANGE HOOD Series CLDA1 and CLSC1 INSTALLATION USE AND CARE MANUAL ...

Page 2: ...commended Tools and Accessories for Installation 7 Install Ductwork Ducted Installations Only 7 Contents 8 Prepare the Hood 9 11 Prepare the Hood Location 12 EZ1 One Person Installation 12 14 Install the Hood EZ1 Bracket 15 16 Standard Installation 17 Install the Hood Standard Installation 18 Connect the Wiring 19 Light Bulbs CLSC1 Series only 20 Install the Filters 20 Wiring Diagrams 21 Service P...

Page 3: ...ncluding fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning ...

Page 4: ...and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION For indoor use only For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors To avoid motor bearing damage and nois...

Page 5: ...beep is heard and LED indicators light up to show the corresponding speed chosen lower LED for LOW speed lower and center LEDs for MEDIUM speed and all LEDs for HIGH speed When blower is on no matter the speed level press and hold this button until the beep sound ends this will turn off the blower and save this blower speed to memory LIGHT BUTTON When lights are OFF press once on this button to tu...

Page 6: ... recirculation filters FAN BLADE The fan blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You...

Page 7: ...GE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3 x 10 or 7 round or horizontally 3 x 10 only 2 Decide where the ductwork will run between the hood and the outdoors 3 Choose a straight short duct run to allow the hood to perform...

Page 8: ... ducting 3 po x 10 po 3 po x 14 po CONDUIT RECTANGULAIRE CONDUIT ROND DE 7 PO OU 3 pulg x 10 pulg 3 pulg x 14 pulg CONDUCTO RECTANGULAR CONDUCTO REDONDO DE 7 PULG O Appuyer ce bord au mur arrière Utiliser ce gabarit pour marquer vos repères ne pas tenter de découper le trou pour le conduit à travers le gabarit NOTE Les découpes incluent le jeu nécessaire à l installation elles ne doivent pas être ...

Page 9: ... filters out 3 Remove the EZ1 brackets from inside the hood by cutting off the tie wrap no EZ1 brackets in CLSC1 Series Remove both screws holding damper assembly to hood Remove parts bag captured behind the damper assembly Remove damper assembly from inside the hood and keep the screws for further use 4 Remove the wiring cover shaded part on illustration below by sliding it out from the hood and ...

Page 10: ...r Cable Knockout from top vertical exhaust or back horizontal exhaust of hood Install an appropriate strain relief 1 2 diameter not included NON DUCTED INSTALLATION ONLY 7 Remove 3 screws retaining the recirculation cover plate shaded part in illustration below to the hood Discard this plate with its screws 7 ROUND DUCT PLATE 2 SCREWS ELECTRICAL POWER CABLE KNOCKOUT ...

Page 11: ... plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIGURE 3 3 X 10 DAMPER ASSEMBLY TOP BACK EDGE OF HOOD DAMPER FLAP PIVOT SCREWS FIGURE 2 A FIGURE 2 B 9 Attach 3 x 10 Damper Assembly on top OR back of hood if using 3 x 10 ...

Page 12: ...une installation sous une armoire à fond en retrait utiliser les lignes pour mesurer l épaisseur du décalage causé par le mur de l armoire et plier le gabarit en conséquence To be translated in Spanish P C CABINET FRONT C L A B VERTICAL EXHAUST A S A A V RTICAL EX 3 x 10 3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through i...

Page 13: ...crews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at A location on template 5 Use a sharp pencil or 1 8 drill bit to mark the locations for the appropriate duct access holes 16 locations for 7 round duct or 4 corner locations for rectangular duct Remove the te...

Page 14: ...on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align the outside edge of the bracket with the marked line keeping the rear end edge leaning on the wall Use a pencil to mark 3 holes Remove the bracket Using a 7 64 drill bit drill 3 holes where marked Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood...

Page 15: ...ts 2 recessed FRONT HOLES C and D While holding the hood attach the power cable to the hood using the strain relief 5 Hang the hood on the brackets using the 2 recessed FRONT HOLES C and D While holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 10 Attach power cable to the hood NOTE See final installation steps on next page HO...

Page 16: ...in parts bag Insert 2 screws per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using 4 no 8 x 5 8 round head wood screws included in parts bag Insert 2 screws in the slots as shown in insets on illustration below FRAMED CABINET FRAMELESS CABINET WOOD SCREWS METAL SCREWS ...

Page 17: ...NG SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 7 16 12 30 HOOD 15 36 HOOD 47 16 CABINET BOTTOM 12 30 HOOD 15 36 HOOD 3 X 10 VERTICAL DUCTING CABINET BOTTOM CABINET FRONT HORIZONTAL DUCT ACCESS HOLE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN WALL 3 CENTER LINE WOOD SHIMS RECESSED BOTTOM CABINETS ONLY 13 16 3 16 5 5 12 30 HOO...

Page 18: ...m 4 mounting screws previously installed Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely Attach power cable to the hood using the strain relief 3 Connect ductwork to hood and use metal foil duct tape to make joints secure and air tight Make sure the damper assembly or round duct plate enters the ductwork and ...

Page 19: ...tandards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally CAUTION Ensure both tabs on inner top of hood are engaged in their corresponding slots in wiring cover Also take care not to pinch wires while reinstalling wiring cover SCREW 2 Reinstall wiring cover and attach it to the hood using its retaini...

Page 20: ...mps during or soon after operation Burns may occur In order to prevent the risk of personal injury only install shielded halogen lamps Also never install a cool beam a dichroic lamp a lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures CAUTION Most GU10 LED replacement bulbs commonly found in the market are not designed for use in a cooking environment and m...

Page 21: ...K High W 120 V AC Line Neutral Ground G Y W BK O R FAN MOTOR BN BN W R BK LED LED W COLOR CODE BK BL BN BN W BLACK BLUE BROWN BROWN WHITE G Y O R W GREEN YELLOW ORANGE RED WHITE 1 2 3 4 5 6 CLDA1 SERIES G Y W BK O R FAN MOTOR BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch Y Low BL High W W BK BK COLOR CODE BK BL BN BLACK BLUE BROWN R W Y RED WHITE YELLOW B...

Page 22: ... PLATE BLACK STAINLESS STEEL INCLUDING SCREWS 1 1 2 SR680508 7 ROUND DUCT PLATE INCLUDING SCREWS 1 1 1 1 1 1 1 3 S97020534 3 X 10 DAMPER ASSEMBLY INCL SCREWS 1 1 1 1 1 1 1 4 S97020408 BLOWER MOTOR INCL 4 SCREWS AND 1 CAPACITOR 1 1 1 1 1 1 1 5 S97020407 FANPELLER INCLUDING ITEM 6 1 1 1 1 1 1 1 6 SR99420635 CLIP FOR FANPELLER 1 1 1 1 1 1 1 7 S99010434 002 GREASE FILTER MICRO MESH TYPE C2 SET OF 2 1 ...

Page 23: ...448 WIRE HARNESS 1 1 1 S98011637 WIRING COVER 1 1 1 S97018623 PARTS BAG INCLUDING 5 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 1 SUCTION CUP TOOL 1 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 1 S99527587 NON DUCTED FILTER CLIP KIT INCLUDES 4 CLIPS 1 1 1 CLSC1 SERIES ITEM NOT SHOWN REPLACEMENT PARTS AND REPAIRS In order to ensure your unit remains in good working condit...

Page 24: ...parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Company reserves the ...

Reviews: