background image

Page 3

CJD1 SERIES

CABINET
BOTTOM

CABINET FRONT

HORIZONTAL DUCT

ACCESS HOLE

5¼"

5¼"

7½"

1/8

"

¾"

13

15/16

(30" hood)

16

15/16

(36" hood)

13

15/16

(30" hood)

HOOD

MOUNTING

SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in wall)

3¾"

16

15/16

(36" hood)

CENTER

LINE

WOOD SHIMS

(recessed-bottom

cabinets only)

19

15/16

(42" hood)

19

15/16

(42" hood)

SOFFIT

24" - 30" ABOVE
COOKING SURFACE

CABINET

3¼" X 10" DUCT
(For horizontal discharge)

WALL CAP

ROOF CAP

3¼" X 10" or 

7" ROUND DUCT 

(For vertical 

discharge)

HOUSE WIRING
(Top or Back of hood)

HOOD

HOOD

PREPARE HOOD LOCATION

PREPARE THE HOOD

Remove 

7” Round Duct Plate from top of hood. Set duct 

plate aside - with mounting screws.

Remove tape holding 

Filters in place. Push back on filter 

finger holes and lift filters out. Set filters aside.

7” ROUND

DUCT PLATE

FILTERS

Determine whether hood will discharge vertically (3¼” x 10” 

or 7” Round), or horizontally (3¼” x 10” only). For vertical or 

horizontal discharge, run ductwork between the hood location 

and a roof cap or wall cap. For best results, use a minimum 

number of transitons and elbows.

Use diagrams, below, for proper placement of ductwork and 

electrical cutout in cabinet or wall. For a non-ducted installa-

tion, DO NOT cut a duct access hole.

Run house wiring between service panel and hood location.

VERTICAL DUCT

ACCESS HOLE

1¼"

1½"

10½"

5¼"

5¼"

CENTER

LINE

HOOD MOUNTING SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in cabinet bottom)

WOOD SHIMS

(recessed-bottom

cabinets only)

CABINET FRONT

CABINET  BOTTOM

13

15/16

(30" hood)

16

15/16

(36" hood)

7½"

5"

2"

19

15/16

(42" hood)

13

15/16

(30" hood)

16

15/16

(36" hood)

19

15/16

(42" hood)

PREPARE HOOD LOCATION

3¼” X 10” 

VERTICAL DUCTING

7” ROUND 

VERTICAL DUCTING

3¼” X 10” 

HORIZONTAL DUCTING

Summary of Contents for CJD1 SERIES

Page 1: ...ERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the fl...

Page 2: ...retailer and attach them to the aluminum mesh filters NOTE For models that are installed in the non ducted mode the most effective operation is achieved at speeds 1 and 2 These speeds provide the mos...

Page 3: ...filters aside 7 ROUND DUCT PLATE FILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round or horizontally 3 x 10 only For vertical or horizontal discharge run ductwork between the...

Page 4: ...thru 13 are for DUCTED INSTALLATION ONLY BAFFLE 7 Remove Air Chute held in place with one 1 screw NOTE Be careful not to disconnect any wires 9 Rotate baffle Re insert baffle into air chute as shown s...

Page 5: ...direction of airflow away from range hood 12 3 x 10 Ducted Discharge Only Remove Tape from damper flap and attach Damper Duct Connector over knockout opening with screws removed in Step 4 under PREPAR...

Page 6: ...urely tighten cable clamp onto house wiring GREEN GROUND SCREW INSTALL THE HOOD KEYHOLE 4 MOUNTING SCREW 4 1 Hang hood from 4 Mounting Screws Slide hood towards wall until mounting screws are engaged...

Page 7: ...includes hardware 15 R99420635 HAIRPIN CLIP 16 R531075 FAN BLADE includes Key No 15 17 R169002 MOTOR MOUNTING SCREWS 3 Req 18 R99080535 MOTOR includes motor mounting kit 19 R111630 LAMP SOCKET HARNES...

Page 8: ...e Limited Warranty Remedy During the applicable limited warranty period the Company will at its option provide replacement parts for or repair or replace without charge any Product or part thereof to...

Page 9: ...TE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUE MADURAS Si las llamas no se apagan de inmediato EVACUEY AVISE A LOS BOMBERO...

Page 10: ...NDA siempre la campana antes de comenzar a cocinar con el fin de establecer un flujo de aire en la cocina Despu s de apagar la es tufa deje que la campana funcione durante unos cuantos minutos para de...

Page 11: ...ltros a un lado PLACA DEL CONDUCTO REDONDO DE 17 8 CM 7 FILTROS 1 Determine si la descarga de la campana va a ser vertical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizonta...

Page 12: ...c tor del conducto para aire 9 Gire el deflec tor Vuelva a insertar el deflector en el conducto para aire de manera seg n lo dem ostrado que las aletas entren totalmente en las ranuras del conducto pa...

Page 13: ...cerca posible del borde superior posterior de la campana CONECTOR DEL REGULADOR DE TIRO CONDUCTO Se muestra la posici n de descarga vertical CINTA AJUSTE LATERAL HASTA DE 2 5 CM 1 PIVOTE BORDE SUPERI...

Page 14: ...trica CABLEADO DOM STICO 120 VCA TORNILLO VERDE DE CONEXI N A TIERRA 1 Cuelgue la campana de los 4 tornillos de montaje que se encuentran en la bolsa de piezas Deslice la campana hacia la pared hasta...

Page 15: ...R 11 401645 CONDUCTO DE AIRE 12 R401647 MONTAJE DE CONDUCTO DE AIRE incluye piezas 13 R602533 TORNILLO DE TIERRA 14 R680504 TAPA DE CABLEADO incluye piezas 15 R99420635 SUJETADOR DE HO RQUILLA 16 R531...

Page 16: ...able la Compa a a su opci n suministrar piezas de repuesto o reparar o reemplazar sin cargo alguno cualquier Producto o pieza del mismo hasta el grado en que la Compa a lo encuentre cubierto bajo esta...

Reviews: