background image

INST

ALLA

TION MANUAL

INST

ALLA

TION

20

Install the Hood (Standard Installation)

1 ]  

Run house power cable between service panel and hood location. Run the house power 
cable into the hood through the strain relief previously installed in step 

6

 on page 13.

2 ]  

Hang hood from (4) mounting screws previously installed. Slide hood back towards wall until 
mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten 
screws securely. Attach power cable to the hood using the strain relief.

DUCTED INSTALLATION ONLY

3 ]  

Connect ductwork to hood and use metal foil duct tape to make joints secure and air-tight. 
Make sure the damper assembly (or round duct plate) enters the ductwork and that the 
damper opens and closes freely.

Summary of Contents for BCDA series

Page 1: ...Serial number 99045652 101C RANGE HOOD Series BCDA BCS3 BCSM NCDA NCS3 and NCSEK INSTALLATION USE AND CARE MANUAL...

Page 2: ...ed Tools and Accessories for Installation 8 Install Ductwork Ducted Installations Only 8 9 Contents 9 10 Prepare the Hood 11 13 Prepare the Hood Location 14 EZ1 Person Installation 14 16 Install the H...

Page 3: ...standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow th...

Page 4: ...d you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fi...

Page 5: ...ght OFF NCSEK SERIES BCSM SERIES ON OFF BLOWER PUSH BUTTON When blower is OFF push on this button to turn ON the blower at the last selected speed Push on this button again to turn OFF the blower NOTE...

Page 6: ...n again until the desired speed is reached from LOW to MEDIUM to HIGH speed to OFF Each time a blower speed is activated a beep is heard and LED indicators light up to show the corresponding speed cho...

Page 7: ...blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liq...

Page 8: ...3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3...

Page 9: ...gle blower hood B double blower hood 4 10 14 8 7 C C C Bend template along graduated scale when installing to framed cabinet Pour une installation sous une armoire fond en retrait utiliser les lignes...

Page 10: ...tenter de d couper le trou pour le conduit travers le gabarit NOTE Les d coupes incluent le jeu n cessaire l installation elles ne doivent pas tre du format exact des conduits Use esta plantilla para...

Page 11: ...p no EZ1 brackets in BCS3 and NCS3 Series Remove both screws holding damper assembly to hood Remove parts bag captured behind the damper assembly Remove damper assembly from inside the hood and keep t...

Page 12: ...Cable Knockout from top vertical exhaust or back horizontal exhaust of hood Install an appropriate strain relief 1 2 diameter not included NON DUCTED INSTALLATION ONLY 7 Remove 3 screws retaining the...

Page 13: ...plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A...

Page 14: ...imple B hotte ventilateur double To be translated in Spanish Electrical access hole center A single blower hood B double blower hood 4 10 14 8 7 C C C Bend template along graduated scale when installi...

Page 15: ...ear end of bracket against the wall Use a pencil to mark 3 holes there are 6 holes but only 3 are necessary Remove the bracket Using a 7 64 drill bit drill 3 holes where marked Assemble the bracket to...

Page 16: ...aw a line on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align side edge to marked line keeping the rear end edge leaning on the wall Use a pencil to mar...

Page 17: ...its 2 recessed REAR HOLES A and B While holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 13 4 Unhook the rear holes from the b...

Page 18: ...o 8 18 x 1 2 metal screws with washers For frameless cabinet secure the hood to the cabinet using four 4 no 8 x 5 8 round head wood screws screws and washers included in parts bag Insert two 2 screws...

Page 19: ...TING SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 7 16 9 24 HOOD 12 30 HOOD 47 16 CABINET BOTTOM 9 24 HOOD 12 30 HOOD 3 X 10 VERTICA...

Page 20: ...4 mounting screws previously installed Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely Attach power cable to...

Page 21: ...andards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally CAUTION Ensure both tabs on inner top of hoo...

Page 22: ...se to install bulb SUCTION CUP TOOL WARNING Do not touch lamps during or soon after operation Burns may occur In order to prevent the risk of personal injury only install shielded halogen lamps Also n...

Page 23: ...R FAN MOTOR BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch BL W W BK BK COLOR CODE BK BL BN BLACK BLUE BROWN R W RED WHITE BN W G Y O BROWN WHITE GREEN YELLOW...

Page 24: ...on back of control board J1 Transformer J2 Power Motor 5 4 3 2 1 5 4 3 2 1 6 7 Control Board R BK R R BL BL BK W BK BK W G Y R Low O Medium BK High W 120 V AC Line Neutral Ground G Y W BK O R FAN MOT...

Page 25: ...Y RED WHITE YELLOW BN W G Y O BROWN WHITE GREEN YELLOW ORANGE 120 V AC Line Neutral Ground 1 2 3 4 5 6 1 2 3 4 5 6 G Y G Y W W W W W BK High BK BK BK O Medium BK O R Low R FAN MOTOR BN W BN Y Low BL...

Page 26: ...FAN MOTOR BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch Y Low BL High W W BK BK COLOR CODE BK BL BN BLACK BLUE BROWN R W Y RED WHITE YELLOW BN W G Y O BROWN...

Page 27: ...EWS 1 S97020031 RECIRCULATION COVER PLATE STAINLESS STEEL INCLUDING SCREWS 1 2 S97018567 7 ROUND DUCT PLATE INCLUDING SCREWS 1 1 1 3 S97020534 3 X 10 DAMPER ASSEMBLY INCLUDING SCREWS 1 1 1 4 S97020408...

Page 28: ...3 CAPTOUCH CONTROL LED BLACK WITH SCREWS 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 4 WASHERS 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK SCREWS 1 1 1 S97020466 NON...

Page 29: ...0448 WIRE HARNESS 1 1 1 1 1 S97018623 PARTS BAG INCLUDING 5 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 1 SUCTION CUP TOOL 1 1 1 1 1 S97020465 NON DUCTED FILTER TYPE XB SET OF 2 NON DUCTED INSTALLATION ONLY 1 1...

Page 30: ...WIRE HARNESS 1 1 1 S97018623 PARTS BAG INCLUDING 5 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 1 SUCTION CUP TOOL 1 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 1 S99527587...

Page 31: ...WS 6 NO 8 X 1 2 COUNTERSUNK SCREWS 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S99527587 NON DUCTED FILTER CLIP KIT INCLUDES 4 CLIPS 1 1 S97020038 SHIELDED HALOGE...

Page 32: ...t parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company...

Reviews: