Page 6

INSTALL THE HOOD 
(Non-Ducted Hoods Only)

NOTE: Non-ducted installations require Non-Duct Kit, 
Model RK58 (purchase separately).

1.  CAUTION: Do not use plastic or rigid metal duct.
2.  Do not remove the protective plastic film covering the 

decorative flue and the hood at this time.

3.  Lay the back side of the hood flat on a table. Use a piece of 

cardboard to avoid damaging the table or the hood.

4.  Attach damper / duct connector to top of hood using (4) #8 

x 3/8” Pan Head mounting screws.

5.  Remove damper flaps from damper / duct connector and 

discard flaps.

NON-DUCT KIT MODEL RK58 CONTENTS

8.  Measure and install steel ductwork to hood duct connector. 

Use duct tape to make all joints secure and air tight.

9.  Hold hood up close to wall mounting location and plug 

power cord into wall outlet.

10. Align the hood and center it above the hood mounting 

bracket. Make sure ductwork on hood lines up and attaches 
to ductwork in ceiling. Gently lower the hood until it securely 
engages the bracket.

11. Use duct tape to make all joints secure and air tight.

INSIDE BACK OF HOOD

MOTOR/BLOWER 

ASSEMBLY

HOLES  

LOCATION

SIDE VIEW

Ø 5/16” TYP.

12. With the hood hanging in place, drill through both holes 

located in the inside lower back of hood using a 5⁄16” drill 
bit. Insert the included drywall anchors into the drilled holes 
(one for each hole). Install (2) washers and (2) #8 x 1-1/2” 
mounting screws through the hood back and into the drywall 
anchors. Verify that the hood is centered and leveled. Tighten 
all screws completely. 

13. Reinstall grease filters by aligning rear filter tabs with slots 

in the hood. Pull down the metal latch tab, push filter into 
position and release. Make sure filters are securely engaged 
after installation.

14. Slightly push aside the upper flue to avoid any damage while 

installing the lower flue to the hood top using (2) #8 x 3/8” 
screws through the lower flue side slots.

15. Slide the upper flue upward until it is aligned with its mounting

bracket. The bracket should be inside the flue. Secure the 
upper flue to the upper flue mounting bracket using (2) #8 x 
3/8” mounting screws.

16. Remove protective plastic film covering the upper flue and 

the hood.

UPPER 

FLUE

UPPER FLUE MOUNTING BRACKET

DUCT LENGTH

DECORATIVE

FLUE

6” ROUND

STEEL DUCT

NON-DUCT

PLENUM

2 TIE

WRAPS

FLEXIBLE DUCT

NON-DUCTED

RECIRCULATION

FILTERS

NON-DUCT PLENUM

COLLAR

8  MOUNTING
SCREWS
(ST4 x 8
Round Head)

MODELS  B5830SS • B5836SS

Page 7

9.  Attach 

aluminum 
flexible 
duct to the 
damper / duct 
connector 
with a tie 
wrap.

10. Attach flexible 

duct to non-
duct plenum 
collar and 
secure with 
tie wrap. Tape 
all joints with 
duct tape.

NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model 
FXN58SS (purchase separately). Discard the upper flue 
supplied with your hood and replace it with the Model 
FXN58SS flue extension.

11. Remove the upper flue from inside the lower flue. Install the 

lower flue bracket to the lower flue using (2) flue bracket 
screws #8 x 3/8”, make sure that the slots are at the top. 
Carefully replace the upper flue inside the lower flue. 
Remove protective plastic film covering the lower flue only.

12. Carefully place both flues into the recessed area of hood 

top. Slightly push aside the upper flue to avoid any damage 
while installing the lower flue to the hood top by using (2) #8 
x 3/8” screws through the lower flue side slots.

13. Attach non-duct plenum with collar to upper flue using (4) 

ST4 x 8 round head screws.

14. Hold hood up close to wall mounting location and plug 

power cord into wall outlet.

15. Align the hood and center it above the hood mounting bracket. 

Gently lower the hood until it securely engages the bracket.

6.  Remove the 

grease filters 
by pulling 
down the 
metal latch 
tab and 
tilting filters 
downward to 
remove.

7.  Attach non-duct collar to non-duct plenum using (4) ST4 x 

8 round head screws.

8.  Measure distance “A”. This will be the length of the 

extended flex duct.

LOWER FLUE MOUNTING BRACKET

LOWER 

FLUE

16. With the hood hanging in place, drill through both holes 

located in the inside lower back of hood using a 5⁄16” drill 
bit. Insert the included drywall anchors into the drilled holes 
(one for each hole). Install (2) washers and (2) #8 x 1-1/2” 
mounting screws through the back of the hood and into 
the drywall anchors. Verify that the hood is centered and 
leveled. Tighten all screws completely.

17. Attach (2) 

two non-duct 
recirculation 
filters to sides 
of blower by 
aligning key lock 
slot and rotating 
until filters lock 
into place.

UPPER 

FLUE

UPPER FLUE MOUNTING BRACKET

A

NON-DUCT PLENUM

6”  ALUMINUM

FLEX  DUCT

DAMPER / DUCT
CONNECTOR

3-5/8”

For replacement non-duct recirculation filters - purchase 
S97018030 or ROUNDFILTER.

18. Reinstall grease filters by aligning rear filter tabs with 

slots in the hood. Pull down the metal latch tab, push filter 
into position and release. Make sure filters are securely 
engaged after installation.

19. Slide up the upper flue upward until it is aligned with its mounting

bracket. The bracket should be inside the flue. Secure the 
upper flue to the upper flue mounting bracket using (2) #8 x 
3/8” mounting screws.

20. Remove protective plastic film covering the flue and the hood.

INSIDE BACK OF HOOD

MOTOR/BLOWER 

ASSEMBLY

HOLES  

LOCATION

SIDE VIEW

Ø 5/16” TYP.

MODELS  B5830SS • B5836SS

Page 8

OPERATION

The hood is operated using the push buttons on the front panel.
Push the light button to turn the lights on and off.
Push the fan controls to select low, medium, or high blower 
speed.
Push the OFF button to turn the blower off.

VQ0010

!

VQ0010

!

OFF

LOW

MED.

HIGH

LIGHT

FAN CONTROLS 

ON/OFF

LIGHT BULBS

VQ0009

!

WARNING

Bulbs may be hot. Always allow bulbs to cool down before 
removing them.

This range hood requires two halogen bulbs (Type JC, 12V, 20W 
Max, G-4 Base).
To change bulbs:
1.  Remove light bulb cover by gently pushing it upward and 

turning it counterclockwise.

2.  Replace bulb. 
3.  Re-install light bulb cover by gently pushing it upward and 

turning it clockwise.

LIGHT BULB COVER

MAINTENANCE

Grease Filters

Grease filters should be cleaned monthly. Remove grease 
filters by pulling down on the metal latch tab. This will 
disengage the filter from the hood. Tilt the filter downward and 
remove.
To clean all-metal filters: Use a warm detergent solution or 
put them in the dishwasher using a non-phosphate detergent. 
Discoloration of the filter may occur if using phosphate 
detergent or as a result of local water conditions - but this will 
not affect filter performance. This discoloration is not covered 
by the warranty.

Non-Duct Recirculation Filters

Change the non-duct recirculation filters every 6 months. 

Rotate the filters to remove them from the blower and replace.

Hood Cleaning

How to maintain the bright look of stainless steel and help 
prevent corrosion.

Dos:

-  Once a month, wash surfaces with clean cloth or rag soaked 

with warm water and mild soap or liquid dish detergent.

-  Always clean in the direction of original polish lines.
-  Always rinse well with clear water (2 or 3 times) after 

cleaning. Wipe dry completely.

-  You may also use a specialized household stainless steel 

cleaner.

Don’ts:

-  Do not use any steel or stainless steel wool or any other 

scrapers to remove stubborn dirt.

-  Do not use any harsh or abrasive cleansers.
-  Do not allow dirt to accumulate.
-  Do not let plaster dust or any other construction residues 

reach the hood. During construction or renovation, cover the 
hood to make sure no dust sticks to stainless steel surface.

Avoid: when choosing a detergent

-  Any cleaners that contain 

bleach

 will attack stainless steel. 

-  Any products containing : 

chloride

fluoride

iodide

bromide

 will deteriorate surfaces rapidly.

-  Any 

combustible products

 used for cleaning such as 

acetone

alcohol

ether

benzol

, etc., are highly explosive 

and should never be used close to a range.

MODELS  B5830SS • B5836SS

Page 9

SERVICE PARTS

WARRANTY

BROAN-NUTONE ONE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of 

original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE.

During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER 

ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper 

maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.

The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the 

above limitation may not apply to you.

BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-

NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of 

any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027    www.broan.com    800-558-1711

Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9    www.broan.ca    877-896-1119

99526964D

KEY  PART NO. 

DESCRIPTION 

QTY.

1  S99526972  Decorative Upper and Lower Flues 

1

2  S99526974  Motor / Blower Assembly 

1

3  S99526975  Light Socket Assembly 

2

4  S99527010  Light Trim Ring / Lens Assembly 

2

5  S99526976  Push Button Assembly 

1

6  S97018027  Aluminum Grease Filters (2 per hood) B5830SS  1

S97018028  Aluminum Grease Filters (3 per hood) B5836SS  1

7  S97018030  Non-Duct Recirculation Filters (pair) 

1

8  S99526983  Damper / Duct Connector 

1

9  S99526984  6” Dia. Expandable Flexible Aluminum Duct 

1

10  S99526992  Non-Duct Plenum Assembly 

1

11  S99526986  Hood Mounting Bracket 

1

12  S99526988  Lower Flue Mounting Bracket 

1

13  S99526990  Upper Flue Mounting Bracket 

1

S99527011  Transformer (not shown) 

1

S99527012  Capacitor (not shown) 

1

S99527013  Plastic Cover (not shown) 

1

S99526993  Parts Bag (not shown) 

1

Order service parts by Part No. - not by Key No.

1

2

4

5

6

7

8

9

10

11

12

13

Replacement parts can be ordered on our website: 

www.broan.com

WIRING DIAGRAM

3

TO  MOTOR

HALOGEN LIGHTS

TRANSFORMER PCB

CAPACITOR

PUSHBUTTON

B

R

N

B

L

K

BLK

BLK

R

W

Y B

R

N

W G

R

Y

B

L

K

O

BLK

W

R

BRN

W

O

R

stop low mid high lamp

GRN

B

L

K BLU

W

GRN / YLW

BROAN - B58 SERIES - RANGE HOODS 

INSTALLATION GUIDE

Reviews: