background image

Page 3

ALLURE

®

 QS1 SERIES

RANGE HOOD  

PREPARE THE  HOOD

3 Remove 

Wiring Cover 

from inside the hood. Set cover and 

mounting screw aside.

Remove either top or back wiring knockout and install 

approved 

Electrical Cable Clamp

.

WIRING 

COVER

ELECTRICAL 

CABLE CLAMP

AIR CHUTE

PREPARE THE  HOOD

5 Remove 

Light Panel 

— held in place with (3) no. 8 screws 

and (2) no. 8 screws. Disconnect light assembly wire 

harness (white connector).

(3) NO. 8 SCREWS

LIGHT

PANEL

Ducted Installation 

 Skip to Step 10.

The following Steps (5 thru 9) are for
NON-DUCTED INSTALLATION ONLY.

 9 

Re-install air chute and screw, re-connect wire harness, 

and replace light panel.

NOTE:  Be careful not to trap wires between 

Support Fin

 

and light panel.

7 Remove 

Baffl e 

from air chute. 

Tabs

 will 

disengage

from 

Slots

.

8 Rotate 

baf

fl

 e. Reinsert 

baf

fl

 e into air chute (as 

shown) so that baf

fl

 e 

fi

 ts all the way into air 

chute. An audible 

“click” will be heard 

when fully installed. 

This will direct air 

fl

 ow through the 

non-ducted slots 

on top of hood.

(2) NO. 8 SCREWS

TABS

BAFFLE

SUPPORT FIN

6 Remove 

Air Chute 

- held in place with 

one (1) screw.

NOTE: Be careful 

not to 

disconnect 

any wires.

SLOTS

Summary of Contents for ALLURE QS1 Series

Page 1: ...bé 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO P...

Page 2: ...ttom cabinets only CABINET BOTTOM CABINET FRONT 7 3 4 HORIZONTAL DUCT ACCESS HOLE HOOD MOUNTING SCREWS 4 1315 16 30 hood 1615 16 36 hood 1915 16 42 hood 1315 16 30 hood 1615 16 36 hood 1915 16 42 hood 5 5 3 1 8 1 Determine whether hood will discharge vertically 3 x 10 horizontally 3 x 10 or non ducted For vertical or horizontal discharge run ductwork between the hood location and a roof cap or wal...

Page 3: ...Skip to Step 10 The following Steps 5 thru 9 are for NON DUCTED INSTALLATION ONLY 9 Re install air chute and screw re connect wire harness and replace light panel NOTE Be careful not to trap wires between Support Fin and light panel 7 Remove Baffle from air chute Tabs will disengage from Slots 8 Rotate baffle Reinsert baffle into air chute as shown so that baffle fits all the way into air chute An...

Page 4: ...place wiring cover PREPARE THE HOOD 10 Remove appropriate Duct Knockout from top or back of hood REAR RECTANGULAR DUCT KNOCKOUT REMOVE FOR 3 X 10 HORIZONTAL DISCHARGE TOP RECTANGULAR DUCT KNOCKOUT REMOVE FOR 3 X 10 VERTICAL DISCHARGE 11 3 x 10 Ducted Discharge Only Attach Damper Duct Connector over knockout opening Make sure damper Pivot is nearest to Top Back Edge of hood Remove Tape from damper ...

Page 5: ... left position is low speed center position is off and right position is high speed An indicator light shows that the fan is on Light The 3 position rocker switch on the right controls the lights The left position is low light intensity center position is off and right position is high light intensity If hood is to be installed Non Ducted Purchase a set of 2 non ducted filters from your local dist...

Page 6: ...l purchase date In the United States contact Broan NuTone LLC 926 West State Street Hartford WI 53027 www broan com 888 336 3948 In Canada contact Broan NuTone Canada 1140 Tristar Drive Mississauga ON L5T 1H9 www broan ca 877 896 1119 SERVICE PARTS KEY NO PART NO DESCRIPTION 2 R740013 Damper Duct Connector includes hardware 3 R602017 Screw no 8 18 x Hex 2 in package 4 R561115 Rocker Switch Almond ...

Page 7: ...roportionnelle à l élément de surface AFIN DE DIMINUER LES RISQUES DE BLESSURES POUVANT SURVENIR LORSQU UN FEU SE DÉCLENCHE SUR LA SURFACE DE CUISSON SUIVEZ CES DIRECTIVES 1 ÉTOUFFEZ LES FLAMMES avec un couvercle hermétique une tôle à biscuits ou un plateau en métal puis éteignez la cuisinière PRENEZ GARDE AUX BRÛLURES Si vous ne parvenez pas à éteindre immédiatement les flammes ÉVACUEZ LES LIEUX ...

Page 8: ...10 po Pour évacuation verticale FIL DU PANNEAU D ALIMENTATION ÉLECTRIQUE Branché sur le dessus ou à l arrière de la hotte HOTTE HOTTE HOTTE 1 Choisissezentreuneévacuationverticale conduitde3 pox10po une évacuation horizontale conduit de 3 po x 10 po et une installation sans conduit Pour les installations à évacuation horizontale ou verticale reliez la hotte à un capuchon de mur ou à un capuchon de...

Page 9: ...lairage maintenu par trois 3 vis no 8 et deux 2 autres vis no 8 Déconnectez les fils pour l éclairage connecteur blanc PANNEAU D ÉCLAIRAGE 3 VIS NO 8 2 VIS NO 8 7 Enlevez le déflecteur du canal Les onglets se désengageront des fentes 8 Faites pivoter le déflecteur Réinsérez le complètement dans le canal comme démontré Un clic sera entendu lorsqu installé correctement Ceci permettra de diriger l ai...

Page 10: ...ssus ou à l arrière de la hotte OUVERTURE ARRIÈRE PRÉAMORCÉE POUR CONDUIT RECTANGULAIRE RETIREZ POUR INSTALLER UN CONDUIT D ÉVACUATION D AIR À L HORIZONTALE DE 3 PO X 10 PO OUVERTURE SUPÉRIEURE PRÉAMORCÉE POUR CONDUIT RECTANGULAIRE RETIREZ POUR INSTALLER UN CONDUIT D ÉVACUATION D AIR À LA VERTICALE DE 3 PO X 10 PO 11 Pourlesinstallationsavecunconduitd évacuationde3 pox10po seulement Fixez le racco...

Page 11: ...um Un voyant vous indique que le ventilateur est en marche Éclairage L éclairage est contrôlé à l aide du commutateur à bascule à trois positions de droite Faites basculer le commutateur vers la position de gauche pour un éclairage minimal vers la position centrale pour éteindre l éclairage et vers la position de droite pour un éclairage maximum Si la hotte est installée sans conduit Procurez vous...

Page 12: ...948 Au Canada contactez Broan NuTone Canada 1140 Tristar Drive Mississauga ON www broan ca 877 896 1119 PIÈCES DE REMPLACEMENT NO NO DE RÉFÉRENCE DE PIÈCE DESCRIPTION 2 R740013 Raccord de conduit avec clapet avec vis d assemblage 3 R602017 Vis no 8 18 x six pans 2 4 R561115 Commutateur à bascule amande 2 R561116 Commutateur à bascule blanc 2 R561117 Commutateur à bascule noir 2 R561119 Commutateur...

Reviews: