MODELS 754RB • 754SN
DECORATIVE SERIES
CEILING VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the ser-
vice disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance
with all applicable codes and standards,
including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combus-
tion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the Ameri-
can Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. NEVER place a switch where it can be
reached from a tub or shower.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently
protected.
CAUTION
!
1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
2. This product is designed for installation in
FLAT CEILINGS ONLY. Do not mount this
product in a wall.
3. The light fixture assembly must be mounted
to the fan housing assembly included with
this product.
Do not mount the light fixture
assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
5. Please read specification label on product for
further information and requirements.
TYPICAL INSTALLATIONS
HOUSING MOUNTED
TO ADDITIONAL FRAMING
Discharge 90
0
to joists.
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
HOUSING MOUNTED
TO 2x
4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING MOUNTED TO 2
x4
TRUSS
Requires additional framing
for mounting tabs.
Discharge 90
0
to joists.
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge 90
0
to joists.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
*
Additional framing must be a 2x6 (minimum height)
*
*
*
*
*