MODELS  754RB • 754SN 

DECORATIVE SERIES

CEILING VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

WARNING  

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE 

THE FOLLOWING:

1.  Use this unit only in the manner intended 

by the manufacturer. If you have questions, 

contact the manufacturer at the address or 

telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch 

power off at service panel and lock the ser-

vice disconnecting means to prevent power 

from being switched on accidentally. When 

the service disconnecting means cannot be 

locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be 

done by a qualified person(s) in accordance 

with all applicable codes and standards, 

including fire-rated construction codes and 

standards.

4.  Sufficient air is needed for proper combus-

tion and exhausting of gases through the flue 

(chimney) of fuel burning equipment to prevent 

backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards 

such as those published by the National Fire 

Protection Association (NFPA), and the Ameri-

can Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the 

local code authorities.

5.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 

utilities.

6.  Ducted fans must always be vented to the 

outdoors.

7.  NEVER place a switch where it can be 

reached from a tub or shower.

8.  This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently 

protected.

CAUTION  

!

1.  For general ventilating use only. Do not use 

to exhaust hazardous or explosive materials 

and vapors.

2.  This product is designed for installation in 

FLAT CEILINGS ONLY. Do not mount this 

product in a wall.

3.  The light fixture assembly must be mounted 

to the fan housing assembly included with 

this product. 

Do not mount the light fixture 

assembly to a wiring outlet box.

4.  To avoid motor bearing damage and noisy 

and/or unbalanced impellers, keep drywall 

spray, construction dust, etc. off power unit.

5.  Please read specification label on product for 

further information and requirements.

TYPICAL INSTALLATIONS

HOUSING MOUNTED

 

TO ADDITIONAL FRAMING

 

Discharge 90

0

 to joists.

HOUSING MOUNTED

DIRECTLY TO JOIST

 

2x6 (or larger)  

Discharge parallel to joists.

HOUSING MOUNTED

 

TO 2x

4 TRUSS

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

HOUSING MOUNTED TO “I” JOIST

Requires additional framing 

for mounting tabs.

Discharge parallel to joists.

HOUSING MOUNTED TO 2

x4 

TRUSS

Requires additional framing 

for mounting tabs.

Discharge 90

0

 to joists.

HOUSING MOUNTED TO “I” JOIST

Requires additional framing 

for mounting tabs.

Discharge 90

0

 to joists.

Installer: Leave this manual with the homeowner.

Homeowner: Use and Care information on page 4.

*

 Additional framing must be a 2x6 (minimum height)

*

*

*

*

*

Summary of Contents for 754RB

Page 1: ...l wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 NEVER place a switch where it can be reached from a tub or shower 8 This unit must be grounded 9 This unit is U L listed Type I C inherently protected CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in FLA...

Page 2: ...best possible performance use the shortest possible duct run and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1 1 1 4 thick ceiling material Holes in corners of housing are labeled with various ceiling material thicknesses Position housing so bottom edge of joist is vi...

Page 3: ...r UL Underwriters Laboratories standards The slightest backdraft however will close the damper flap preventing air from entering unit or finished space 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive another nail through the top hole of each mounting bracket Existing Construction...

Page 4: ...ation of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR...

Page 5: ...ladores con conductos siempre deben tener salida hacia el exterior 7 Nunca coloque el interruptor en un lugar en donde se pueda alcanzar desde la tina o ducha 8 Esta unidad se debe conectar a tierra 9 Esta unidad está incluida en la lista de U L Tipo I C proteger inherente PRECAUCIÓN 1 Esta unidad debe usarse solamente para ventilación general No la utilice para la descarga de materiales ni vapore...

Page 6: ... de manera que el borde inferior de la cubierta quede al ras del cielo raso terminado Característica adicional para la colocación en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 3 2 cm Los orificios que se encuentran en las esquinas de la cubierta están marcados con varios espesores del material del cielo raso Coloque la cubierta de manera que el borde inferior de la vigue ta sea visible a tr...

Page 7: ...ta La parte superior del conec tor del regulador de tiro conducto debe quedar al ras de la parte superior de la cubierta 2 Conecte el conducto redondo de 4 10 2 cm en el conector del regulador de tiro conducto y extienda el conducto hasta el exterior a través de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que abre libremente Coloque cinta en todas las conexiones de ...

Page 8: ...s de instalación La duración de cualquier garantía implícita se limita a un período de un año según se especifica en la garantía explícita Algunos estados no permiten limitación a la duración de una garantía implícita por lo que esta limitación tal vez no se aplica al caso suyo LA OBLIGACION DE BROAN NUTONE DE REPARAR O CAMBIAR A OPCION DE BROAN NUTONE SERA EL UNICOY EXCLUSIVO REMEDIO AL COMPRADOR...

Reviews: