4
INSTALL RANGE HOOD
WARNING
TURN OFF THE PROPER CIRCUIT AT THE SERVICE EN-
TRANCE BEFORE WIRING THIS RANGE HOOD.
1. Run power cable from location of switches to hood location
and through hole drilled in wall or cabinet. Split wiring for 6"
and install proper connector for type of wire used.
CONNECTOR
2. Position hood so that:
a.)Power cable is routed through knockout opening
b.)Large part of keyhole slots fit over hood mounting screws.
c.) Damper/duct connector slides into ductwork.
3. Adjust hood so that hood front is flush with cabinet frame.
4. Tighten hood mounting screws firmly.
5. Fasten wiring to hood with proper electrical connector for type
of wire being used.
WARNING
ALL ELECTRICAL CONNECTIONS MUST BE IN ACCOR-
DANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL
ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METH-
ODS OF INSTALLING ELECTRICAL WIRING, SECURE THE
SERVICES OF A QUALIFIED ELECTRICIAN.
6. Strip 1/2" of insulation from wires. Connect white to white,
black to black, red to red and green or bare wire beneath
green ground screw (provided).
7. Replace wiring box cover and screw. Make sure that all wir-
ing is safely contained inside.
INSTALL RANGE HOOD
(CONTINUED)
8. Install light (75 Watt maximum). For easier installation,
squeeze plastic lens and remove it from hood. Remember to
reinstall lens.
9. Turn on power and check operation of fan and light. Make
sure that damper operates freely.
SOCKET
LIGHT LENS
RED
TO
RED
WHITE
TO
WHITE
GROUND (Bare
or green wire)
BLACK
TO
BLACK
IMPORTANT:
This hood is designed to be controlled using (2) separate, gen-
eral-use wall switches. Use
3-wire plus ground power cable
be-
tween switches and hood.
LIGHT
SWITCH
FAN
SWITCH
LIGHT
BLACK
RED
WHITE
FAN
GROUND
BLACK
RED
WHITE
3-wire plus ground
power cable
WHITE
BLACK
WHITE
GROUND
120 VAC
LINE IN
RANGE HOOD
WIRING SCHEMATIC
RANGE HOOD WIRING
3-WIRE PLUS GROUND
POWER CABLE
Summary of Contents for 53000 SERIES
Page 8: ...99043003B...