MODELS   350 • 350BK • 350BR • 355 • 355BK • 355BR

356 • 356BK • 356BR • 358

WARNING 

 

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 

TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment manufac-

turer's guidelines and safety standards such as those published 

by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Condition-

ing Engineers (ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  The wiring must be permanent. DO NOT USE AN EXTENSION 

CORD! Use 14 GA. MINIMUM copper wire. Although the Powered 

Attic Ventilator may be wired directly to power, we advise that 

some type of shut off switch be installed in the line. Please see 

the section on electrical wiring for suggested wiring diagrams 

and instructions.

7.  This unit must be grounded.
8.  Do not use this unit with any solid state speed control device 

(Models 356 and 358 only).

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

3.  This unit has an unguarded impeller. Do not use in locations 

readily accessible to people or animals.

4.  Fan is equipped with a thermostat which may start fan automati-

cally. To reduce risk of injury or electric shock while servicing or 

cleaning unit, switch power off at service panel and lock service 

panel to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a tag, to 

the service panel.

5.  Home Ventilating Institute (HVI) recommends one square foot 

of open air inlet per 300 cfm of fan capacity. The best location 

for these air intake vents are under the eaves with direct ac-

cess to the attic. Failure to provide these intakes could cause 

natural-draft gas appliances to backdraft.

6.  Your attic fan installation will create a screened opening into 

your attic space. During a heavy rain storm there could be a 

light spray of rain into this attic space. This is a normal condi-

tion with all attic ventilators and will not cause any damage to 

the structure. We recommend that you do not store any valu-

able articles directly under the fan opening in the roof. During 

extreme rain and wind storms you may want to turn on your 

attic ventilator to prevent excess moisture accumulation in your 

attic.

7.  Records show, under ideal conditions, exposed galvanized steel 

can remain rust free up to 100 years. For best protection, the 

exposed portion of the roof sheet should be painted, especially 

in areas of unusually high industrial air pollution. Follow paint 

manufacturer's instructions for good adhesion.

8.  This ventilator is intended for roof installation. The Broan Model 

353 Gable Mount Ventilator is available for side wall applications.

9.  The dome may be painted with a high-quality paint. Follow 

the paint manufacturer's recommendations for PVC plastic or 

aluminum, as appropriate.

10. Please read specification label on product for further information 

and requirements.

ROOF-MOUNT 

POWERED ATTIC VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

Slotted Screwdriver

Drill

1/4" Drill Bit

Sabre Saw or Keyhole Saw

Hammer

Ruler

TOOLS AND MATERIALS REQUIRED

Pencil

Utility Knife

Pry Bar (to remover roofing nails)

Roofing Cement

Galvanized Roofing Nails (1¾" min.)

Electrical Supplies (to comply with codes)

Summary of Contents for 350

Page 1: ... in locations readily accessible to people or animals 4 Fan is equipped with a thermostat which may start fan automati cally To reduce risk of injury or electric shock while servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning...

Page 2: ...entilator top is level with the roof peak it can t be seen from the street Keep this approximate location in mind as you work from within the attic 2 Mark a spot halfway between rafters 3 Drill a guide hole through the roof at this mark 4 Cut out the template found on the carton 5 Push a large nail through the center of the cardboard template and into the guide hole Usingthelargehalfofthetemplate ...

Page 3: ...ate 8 Drill a large starting hole for the sabre saw just inside of the line 9 Cut out the roof board s inside of the line 10 For proper removal of roofing nails draw a 22 square centeredaroundthehole Removenailsholdingshingles down from top two thirds of square 11 Slide the flashing under the shingles Start two thirds of the way down from the top of the 22 square Do not bend the shingles any more ...

Page 4: ...356BR 358 Page 4 12 Carefully lift shingles and nail flashing securely to the roof using galvanized roofing nails 13 Using a good grade of roofing cement material seal all of the shingles and heads of nails DO NOT seal the bottom edge of the flashing ...

Page 5: ...N OFF SWITCH MOTOR VENTILATOR WIRING BOX MASTER ON OFF SWITCH BLK GRD WHT BLK GRD WHT THERMOSTAT BY PASS SWITCH RED BLACK This diagram shows how to wire a humidistat 3 Replace the metal cover plate over the thermostat wiring box and fasten securely 4 The thermostat setting determines the temperature at which the ventilator turns on The ventilator automatically turns off when the attic temperature ...

Page 6: ...1 2 3 Required 10 99170245 8B 18 x 3 8 Sheet Metal Screw 3 Required 11 98009756 Wiring Box Models 350 350BK 350BR 355 355BK 355BR 358 98009886 Wiring Box Models 356 356BK 356BR 12 99150471 Green Ground Screw 10 32 x 1 2 Hex Washer Head 13 99030144 Adjustable Thermostat 14 97005329 Lead Wire Assembly 15 16 990717160 Wiring Box Cover with Label Model 350 990717161 Wiring Box Cover with Label Model 3...

Page 7: ...Page 7 MODELS 350 350BK 350BR 355 355BK 355BR 356 356BK 356BR 358 SERVICE PARTS Replacement parts can now be ordered on our website Please visit us at www Broan com ...

Page 8: ...f any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDE...

Reviews: