background image

 

 

DiViNe Route 66

 

15 / 18 

rev. 1.2 

  

Technical Specifications 

 

Video 

 

 

Standards 

SD, ED, HD, Dual Link, 3G 

 

Complies with SMPTE 

259M, 292M, 344M, 372M, 424M 

 

Interface 

SDI – Serial Digital Interface 

 

 

Optical Connection 

Complies with 21 CFR 1040.10 and 1040.11 

 

 

SANE, LAN 

Convention 

 

Audio 

TIA - 568A/B, Optocore 

200 Mbit/s 

LAN 

TIA - 568A/B, IEEE - 802.3 

10/100 Mbit/s 

 

Word clock 

Hardware standard BNC - 75 

Ω

  

 

Data rate 

Depending on selected sample rate 

Up to 192 kHz 

Impedance 

Output  

 5 

Ω

 

 

Input 

75 

Ω

 

Drive level 

Output 

 1 V

pp  

Zero level 

Referring to GND 

+ 1.7 V 

Sense level 

Input  

 400 mV

pp 

 

Remote Control 

Convention 

 

RS232 

EIA / TIA - 232 

57 600 Baud 

USB 

USB 2.0 - Device 

12 Mbit/s 

LAN 

IEEE - 802.3 

10/100 Mbit/s 

 

Power supply 

 

Type 

Switch-mode, universal input 

Mains voltage 

100 

 240 V 

Frequency 

50 

 60 Hz 

Power consumption 

Depending on device, 32VA - Max 

Security classification 

Class 1: basic insulation, connected to the protective grounding conductor 

Security regulations 

Harmonised European standard EN60065 

Mains connector 

acc. to IEC-950 

Cooling 

Passive, via surface and ventilation-slits on both sides 

Summary of Contents for DiViNe Route 66

Page 1: ...ideo Network Operating Manual Rev 1 2 Operating Manual for DiViNe Route 66 Digital Video Network device with Optocore and SANE Copyright 2017 All rights reserved BROAMAN GmbH Lohenstr 8 82166 Munich Gräfelfing Germany ...

Page 2: ... the power cord from being stepped on crushed pinched or damaged in any other way Pay special attention to plugs and sockets of the device Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plug These must be freely accessible at all times The device should be dis...

Page 3: ... and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for use in moderate climates Ventilation Do not block or cover any ventilation slits Install the device in accordance with the operating manual Leave sufficient venti...

Page 4: ... Interference by means of external objects and or liquids with the device Never push objects of any kind into the device through openings in the casing They may come into contact with dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the device Cables and Accessories Only use attachments specified by the manufacturer Only us...

Page 5: ...ful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to c...

Page 6: ...k 11 Transmission Delay 11 Power Supply 11 Control 12 Connectors and Cables 12 Optical Connection 12 SD HD 3G Ports 12 SANE Ports 12 Auxiliary Ports 12 RS232 Connection 12 Connector Hood Quality 12 USB Connection 12 LAN Connection 12 Word Clock Connection 12 Mains Connection 12 Connection Example 13 Connection Tables 14 Technical Specifications 15 Dimensions and Weight 16 Warranty and Liability 17...

Page 7: ...tical fiber Every single Route 66 product is different and customised to meet even the most sophisticated requirements Route board is capable of handling up to 66 video channels Each Route66 is being delivered in 2RU frame which is equipped with up to 24 BNC ports for SD HD 3G video 20 duplex LC fiber ports and additionally up to 36 simplex LC fiber ports Additionally Route 66 is equipped with sta...

Page 8: ...munication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Master LED Indicates the master unit OPTO LED Optocore communication is established SANE LED SANE communication is established Device ID Display Indicates the identifica...

Page 9: ...anel S2 Ethernet communication is established via SANE 2 rear panel UP There is other device with physical Ethernet port enabled on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel POWER MUTE Mic Card Phantom Power Output Card Mute Sample rate LED Yellow 44 1 48 88 2 96 176 4 192 kHz ...

Page 10: ...SFP fiber ports with TX and RX Each port can be configured by manufacturer as Video Link or Optocore Link for Optocore Router Word Clock IN BNC Word clock input allows synchronization of Optocore devices to an external word clock source Word Clock OUT BNC Word clock output for synchronization of external devices SANE 1 SANE RJ 45 interface for data transmission 100 Mbit Ethernet SANE 2 SANE RJ 45 ...

Page 11: ... control data OPTOCORE CONTROL software is used for setting the destination of each interface Word Clock All units are equipped with a Word Clock IN and OUT Word Clock is also transmitted via the fiber and SANE Ports In network configurations no extra BNC cable is needed The X6R V3R FX INTERCOM units are equipped with an internal high quality and extremely low jitter word clock Any X6R V3R FX INTE...

Page 12: ...e available along with matching inter connection cables transported on cable drums Please refer to Product Brochure available at www BroaMan com SD HD 3G Ports Coaxial 75 Ω cable with BNC connectors compliant with digital SD HD 3G standard can be used The maximum distance is 300 m SANE Ports Use standard twisted 4 pair cable Cat 5 Cat 5e Cat 6 with RJ 45 connectors SANE technology utilises all 4 p...

Page 13: ... each locations it is possible to connect Repet48WDM unit which is equipped with two SD HD 3G outputs four inputs and two fiber optic tunnels for OPTOCORE protocol transport Connections between Route66 and both Repeat48WDM are done by fiber cables Routing in Route66 platform may be set to the fixed layout or be controlled by user with a controlling software platform like VSM Fig 1 Connection of on...

Page 14: ... 2 3 4 Pin 1 2 3 4 5 6 7 8 9 D Sub 9 female Error Not a valid embedded object Locking system acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally bridged Power Use standard RS232 cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 female Error Not a valid embedded object Locking system acc to 4 40 UNC Pin out USB Port Channel USB GND USB device connector VBUS D ...

Page 15: ...92 kHz Impedance Output 5 Ω Input 75 Ω Drive level Output 1 Vpp Zero level Referring to GND 1 7 V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN IEEE 802 3 10 100 Mbit s Power supply Type Switch mode universal input Mains voltage 100 240 V Frequency 50 60 Hz Power consumption Depending on device 32VA Max Security classification C...

Page 16: ...46 inch 2RU frame 44 mm 1 73 inch 1RU frame depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight Dependent on components and port configuration of each specific device Modifications that serve the purpose of technical improvement of the device may be carried out without prior notification ...

Page 17: ...distributors dealers Always ensure the careful handling of the device If possible these devices should always be transported or shipped in special shock absorbing transport cases If these are not available we recommend well padded packaging such as the coated carton in which the device was delivered We strongly advise not to use simple flight cases without rack in rack mounting Declaration of Liab...

Page 18: ...iNe Route 66 18 18 rev 1 2 Company Information Mailing Address BROAMAN GmbH Lohenstr 8 D 82166 Munich Gräfelfing Germany Telephone 49 0 89 8999640 Facsimile 49 0 89 89996455 Internet www BroaMan com Email ...

Reviews: