DiViNe Route 66
12 / 18
rev. 1.2
Control
Route66 device doesn’t require any software to be fully operable. Each unit is set up by manufacturer according
to the requirements and no further configuration is necessary. However it is possible to set routing via 3
rd
party
platform like VSM. It is also possible to change RS485/422 setting and device ID with Optocore Control Software.
The RS232, LAN or USB port enables the configuration of one unit attached directly to the PC. For further
information please contact BroaMan Support team.
Connectors and Cables
Optical Connection
All optical interfaces are equipped with duplex LC connectors on commonly used SFP transceivers (please note
that all SFP transceivers are build in one board, because high speed connections are required – it means that
only some of the SFPs are user-changeable and the rest can be changed only by manufacturer). User can plug
singlemode or multimode transceiver. Standard LC cables with two fibers can be used. Worst case reach is
700 m with multimode transceivers and a 50
µ
m fiber, whilst with monomode transceivers and a 9
µ
m fiber, up to
70 km are possible. For rugged applications e.g. touring and other temporary installations, HMA Expanded Beam
Connectors mounted on 1 RU panel are available, along with matching, inter-connection cables transported on
cable drums. (Please refer to Product Brochure available at
www.BroaMan.com
).
SD/HD/3G Ports
Coaxial 75
Ω
cable with BNC connectors compliant with digital SD/HD/3G standard can be used. The maximum
distance is 300 m.
SANE Ports
Use standard twisted-4-pair-cable (Cat-5, Cat-5e, Cat-6), with RJ-45 connectors. SANE technology utilises all 4
pairs of Cat-5 cable – two for standard Ethernet transmission, two for SANE.
Auxiliary Ports
According to the RS422/RS485 hardware standard, each channel requires a twisted pair. A common braided
shield should enclose the pairs.
RS232-Connection
Shielded, standard RS232 cable is sufficient for the RS232 port.
Connector Hood Quality
Applied locking screws for the D-Sub-types must be acc. to 4-40 UNC. Care should be taken in selecting the right
types of connector hoods in order to fulfil the requirements of EMI-radiation directives. Full metal connector hoods
should be used, approved acc. to VDE 0871, FCC 20780 and EMC directive 2004/108/EG, providing a reduction
> 40 dB on 30 MHz up to 1 GHz. The shielding harness of the cable should have complete contact to the
connector hood
.
USB-Connection
To the USB-port, use a standard PC/device cable.
LAN-Connection
Use standard twisted-pair-cable (Cat-5, Cat-6) with RJ-45 connector.
Word Clock-Connection
Use 75
Ω
-coaxial-cable with BNC-connector.
Mains-Connection
Standard power cords with IEC C13 sockets can be used.