BroaMan DiViNe Route 66 Operating Manual Download Page 12

 

 

DiViNe Route 66

 

12 / 18 

rev. 1.2 

  

Control 

Route66 device doesn’t require any software to be fully operable. Each unit is set up by manufacturer according 
to the requirements and no further configuration is necessary. However it is possible to set routing via 3

rd

 party 

platform like VSM. It is also possible to change RS485/422 setting and device ID with Optocore Control Software. 
The  RS232,  LAN  or  USB  port  enables  the  configuration  of  one  unit  attached  directly  to  the  PC.  For  further 
information please contact BroaMan Support team. 

 
Connectors and Cables 

Optical Connection 

All optical interfaces are equipped with duplex LC connectors on commonly used SFP transceivers (please note 
that  all  SFP  transceivers  are  build  in  one  board,  because  high  speed  connections  are  required  –  it  means  that 
only some of the SFPs are user-changeable and the rest can be changed only by manufacturer). User can plug 
singlemode  or  multimode  transceiver.  Standard  LC  cables  with  two  fibers  can  be  used.  Worst  case  reach  is 
700 m with multimode transceivers and a 50 

µ

m fiber, whilst with monomode transceivers and a 9 

µ

m fiber, up to 

70 km are possible. For rugged applications e.g. touring and other temporary installations, HMA Expanded Beam 
Connectors  mounted  on  1  RU  panel  are  available,  along  with  matching,  inter-connection  cables  transported  on 
cable drums. (Please refer to Product Brochure available at 

www.BroaMan.com

). 

SD/HD/3G Ports 

Coaxial 75 

Ω

 cable with BNC connectors compliant with digital SD/HD/3G standard can be used. The maximum 

distance is 300 m. 

SANE Ports 

Use standard twisted-4-pair-cable (Cat-5, Cat-5e, Cat-6), with RJ-45 connectors. SANE technology utilises all 4 
pairs of Cat-5 cable – two for standard Ethernet transmission, two for SANE.  

Auxiliary Ports 

According  to  the  RS422/RS485  hardware  standard,  each  channel  requires  a  twisted  pair.  A  common  braided 
shield should enclose the pairs. 

RS232-Connection 

Shielded, standard RS232 cable is sufficient for the RS232 port. 

Connector Hood Quality 

Applied locking screws for the D-Sub-types must be acc. to 4-40 UNC. Care should be taken in selecting the right 
types of connector hoods in order to fulfil the requirements of EMI-radiation directives. Full metal connector hoods 
should be used, approved acc. to VDE 0871, FCC 20780 and EMC directive 2004/108/EG, providing a reduction 
>  40 dB  on  30 MHz  up  to  1 GHz.  The  shielding  harness  of  the  cable  should  have  complete  contact  to  the 
connector hood

.

  

USB-Connection 

To the USB-port, use a standard PC/device cable. 

LAN-Connection 

Use standard twisted-pair-cable (Cat-5, Cat-6) with RJ-45 connector.  

Word Clock-Connection 

Use 75 

Ω

-coaxial-cable with BNC-connector.   

Mains-Connection 

Standard power cords with IEC C13 sockets can be used.

Summary of Contents for DiViNe Route 66

Page 1: ...ideo Network Operating Manual Rev 1 2 Operating Manual for DiViNe Route 66 Digital Video Network device with Optocore and SANE Copyright 2017 All rights reserved BROAMAN GmbH Lohenstr 8 82166 Munich Gräfelfing Germany ...

Page 2: ... the power cord from being stepped on crushed pinched or damaged in any other way Pay special attention to plugs and sockets of the device Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plug These must be freely accessible at all times The device should be dis...

Page 3: ... and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for use in moderate climates Ventilation Do not block or cover any ventilation slits Install the device in accordance with the operating manual Leave sufficient venti...

Page 4: ... Interference by means of external objects and or liquids with the device Never push objects of any kind into the device through openings in the casing They may come into contact with dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the device Cables and Accessories Only use attachments specified by the manufacturer Only us...

Page 5: ...ful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to c...

Page 6: ...k 11 Transmission Delay 11 Power Supply 11 Control 12 Connectors and Cables 12 Optical Connection 12 SD HD 3G Ports 12 SANE Ports 12 Auxiliary Ports 12 RS232 Connection 12 Connector Hood Quality 12 USB Connection 12 LAN Connection 12 Word Clock Connection 12 Mains Connection 12 Connection Example 13 Connection Tables 14 Technical Specifications 15 Dimensions and Weight 16 Warranty and Liability 17...

Page 7: ...tical fiber Every single Route 66 product is different and customised to meet even the most sophisticated requirements Route board is capable of handling up to 66 video channels Each Route66 is being delivered in 2RU frame which is equipped with up to 24 BNC ports for SD HD 3G video 20 duplex LC fiber ports and additionally up to 36 simplex LC fiber ports Additionally Route 66 is equipped with sta...

Page 8: ...munication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Master LED Indicates the master unit OPTO LED Optocore communication is established SANE LED SANE communication is established Device ID Display Indicates the identifica...

Page 9: ...anel S2 Ethernet communication is established via SANE 2 rear panel UP There is other device with physical Ethernet port enabled on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel POWER MUTE Mic Card Phantom Power Output Card Mute Sample rate LED Yellow 44 1 48 88 2 96 176 4 192 kHz ...

Page 10: ...SFP fiber ports with TX and RX Each port can be configured by manufacturer as Video Link or Optocore Link for Optocore Router Word Clock IN BNC Word clock input allows synchronization of Optocore devices to an external word clock source Word Clock OUT BNC Word clock output for synchronization of external devices SANE 1 SANE RJ 45 interface for data transmission 100 Mbit Ethernet SANE 2 SANE RJ 45 ...

Page 11: ... control data OPTOCORE CONTROL software is used for setting the destination of each interface Word Clock All units are equipped with a Word Clock IN and OUT Word Clock is also transmitted via the fiber and SANE Ports In network configurations no extra BNC cable is needed The X6R V3R FX INTERCOM units are equipped with an internal high quality and extremely low jitter word clock Any X6R V3R FX INTE...

Page 12: ...e available along with matching inter connection cables transported on cable drums Please refer to Product Brochure available at www BroaMan com SD HD 3G Ports Coaxial 75 Ω cable with BNC connectors compliant with digital SD HD 3G standard can be used The maximum distance is 300 m SANE Ports Use standard twisted 4 pair cable Cat 5 Cat 5e Cat 6 with RJ 45 connectors SANE technology utilises all 4 p...

Page 13: ... each locations it is possible to connect Repet48WDM unit which is equipped with two SD HD 3G outputs four inputs and two fiber optic tunnels for OPTOCORE protocol transport Connections between Route66 and both Repeat48WDM are done by fiber cables Routing in Route66 platform may be set to the fixed layout or be controlled by user with a controlling software platform like VSM Fig 1 Connection of on...

Page 14: ... 2 3 4 Pin 1 2 3 4 5 6 7 8 9 D Sub 9 female Error Not a valid embedded object Locking system acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally bridged Power Use standard RS232 cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 female Error Not a valid embedded object Locking system acc to 4 40 UNC Pin out USB Port Channel USB GND USB device connector VBUS D ...

Page 15: ...92 kHz Impedance Output 5 Ω Input 75 Ω Drive level Output 1 Vpp Zero level Referring to GND 1 7 V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN IEEE 802 3 10 100 Mbit s Power supply Type Switch mode universal input Mains voltage 100 240 V Frequency 50 60 Hz Power consumption Depending on device 32VA Max Security classification C...

Page 16: ...46 inch 2RU frame 44 mm 1 73 inch 1RU frame depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight Dependent on components and port configuration of each specific device Modifications that serve the purpose of technical improvement of the device may be carried out without prior notification ...

Page 17: ...distributors dealers Always ensure the careful handling of the device If possible these devices should always be transported or shipped in special shock absorbing transport cases If these are not available we recommend well padded packaging such as the coated carton in which the device was delivered We strongly advise not to use simple flight cases without rack in rack mounting Declaration of Liab...

Page 18: ...iNe Route 66 18 18 rev 1 2 Company Information Mailing Address BROAMAN GmbH Lohenstr 8 D 82166 Munich Gräfelfing Germany Telephone 49 0 89 8999640 Facsimile 49 0 89 89996455 Internet www BroaMan com Email ...

Reviews: