SYSTEM CVs
CV65
Kick-Start
Description
This Value Allows Additional Motor Power to Overcome Initial
Inertia at Locomotive Starts
Values
0-255
Initial Value
40
Related CVs
Bit 7
Bit 0
0
0
1
0
1
0
0
0
The kick-start is only enabled when the backemf is disabled. See
CV10 on backemf disabling. The kick-start value is added to the
motor power startup voltage (CV2) for a short duration of time and
only during the transition from speed step zero to speed step one.
The kick-start value is decreased form its initial value slowly to zero,
allowing a smoother operation.