154
SETUP CVs
CV189
Motor Load Chuff Power Filter
Description
This Value Sets the Motor Load Power’s Filter Convergence Time
Values
0-255
Initial Value
12
Related CVs
Bit 7
Bit 0
0 0 0 0 1 1 0 0
The locomotive’s power is monitored and filtered, thus tracking
the amount of power used at any given instance. If the power
requirement change enough, the chuff sound effects change,
following the power requirements. This value determines the
convergence time of the reading. Increasing the value increases
the accuracy, but increases the response time. Decreasing the
value decreases the response time but also decreases the accuracy.