![Broadway Limited Paragon 3 Reference Manual Download Page 179](http://html.mh-extra.com/html/broadway-limited/paragon-3/paragon-3_reference-manual_2815869179.webp)
179
CONTROL CVs
CV241
Random Sound Effect Generator Timer High
Description
This Value Contains the DCC Startup Timer
Values
1-255
Initial Value
20
Related CVs
Bit 7
Bit 0
0 0 0 1 0 1 0 0
This value determines how often random sound effects occur. A
random sound cannot occur later than this value. This timer is
measured in seconds and starts timing after the present random
sound effects finishes.
Note: This number must be larger than
CV240.