February 26, 2018 • NetXtreme-E-UG100
Page 41
System-level Configuration
NetXtreme-E User’s Manual
•
P1 – port 1 setting
•
P2 – port 2 setting
•
AN – auto-negotiation
•
No AN – forced speed
Table 24: Supported Combination of Link Speed Settings
Port1 Link Speed
Setting
Port 2 Link Setting
Forced 1G
Forced 10G
Forced 25G
AN Enabled {1G}
AN Enabled
{10G}
AN Enabled
{25G}
AN Enabled {1/
10G}
AN Enabled {1/
25G}
AN Enabled {10/
25G}
AN Enabled {1/10/
25G}
Forced 1G
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P2: no AN
P2: no AN
P2: no AN
P2: {1G}
P2: AN {10G}
P2: AN {25G}
P2: AN {1/10G}
P2: AN {1/25G}
P2: AN {10/25G}
P2: AN {1/10/25G}
Forced 10G
P1: no AN
P1: no AN
Not supported
P1: no AN
P1: no AN
Not supported
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P2: no AN
P2: no AN
P2: {1G}
P2: {10G}
P2: AN {1/10G}
P2: AN {1G}
P2: AN {10G}
P2: AN {1/10G}
Forced 25G
P1: no AN
Not supported
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P1: no AN
P2: no AN
P2: no AN
P2: no AN
P2: no AN
P2: no AN
P2: AN {1G}
P2: AN {1/25G}
P2: AN {25G}
P2: AN {1/25G}
AN Enabled
{1G}
P1: {1G}
P1: {1G}
P1: {1G}
P1: AN {1G}
P1: AN {1G}
P1: AN {1G}
P1: AN {1G}
P1: AN {1G}
P1: AN {1G}
P1: AN {1G}
P2: no AN
P2: no AN
P2: no AN
P2: AN {1G}
P2: AN {10G}
P2: AN {25G}
P2: AN {1/10G}
P2: AN {1/25G}
P2: AN {10/25G}
P2: AN {1/10/25G}
AN Enabled
{10G}
P1: AN {10G}
P1: AN {25G}
Not supported
P1: AN {10G}
P1: AN {10G}
Not supported
P1: AN {25G}
P1: AN {10G}
P1: AN {10G}
P1: AN {10G}
P2: no AN
P2: no AN
P2: AN {1G}
P2: AN {10G}
P2: AN {1G}
P2: AN {1G}
P2: AN {10G}
P2: AN {1/10G}
AN Enabled
{25G}
P1: AN {25G}
Not supported
P1: AN {25G}
P1: AN {25G}
Not supported
P1: AN {25G}
P1: AN {1/10G}
P1: AN {25G}
P1: AN {25G}
P1: AN {25G}
P2: no AN
P2: no AN
P2: AN {1G}
P2: AN {25G}
P2: AN {1/10G}
P2: AN {1/25G}
P2: AN {25G}
P2: AN {1/25G}
AN Enabled
{1/10G}
P1: AN {1/10G} P1: AN {1/10G} P1: AN {1G}
P1: AN {1/10G}
P1: AN {1/10G}
P1: AN {1/10G}
P1: AN {1/25G}
P1: AN {1G}
P1: AN {1/10G}
P1: AN {1/10G}
P2: no AN
P2: no AN
P2: no AN
P2: AN {1G}
P2: AN {10G}
P2: AN {25G}
P2: AN {1/10G}
P2: AN {1G}
P2: AN {10G}
P2: AN {1/10G}
AN Enabled
{1/25G}
P1: AN {1/25G} P1: {1G}
P1: AN {1/25G} P1: AN {1/25G}
P1: AN {1G}
P1: AN {1/25G}
P1: AN {10/25G}
P1: AN {1/25G}
P1: AN {1/25G}
P1: AN {1/25G}
P2: no AN
P2: no AN
P2: no AN
P2: AN {1G}
P2: AN {10G}
P2: AN {25G}
P2: AN {1/10G}
P2: AN {1/25G}
P2: AN {25G}
P2: AN {1/25G}
AN Enabled
{10/25G}
P1: AN {10/
25G}
P1: {10G}
P1: AN {25G}
P1: AN {10/25G}
P1: AN {10G}
P1: AN {25G}
P1: AN {1/10/25G}
P1: AN {25G}
P1: AN {10/25G}
P1: AN {10/25G}
P2: no AN
P2: no AN
P2: no AN
P2: AN {1G}
P2: AN {10G}
P2: AN {25G}
P2: AN {1/10G}
P2: AN {25G}
P2: AN {10/25G}
P2: AN {1/10/25G}
AN Enabled
{1/10/25G}
P1: AN {1/10/
25G}
P1: {1/10G}
P1: AN {1/25G} P1: AN {1/10/
25G}
P1: AN {1/10G}
P1: AN {1/25G}
P1: AN {1/10/25G}
P1: AN {1/25G}
P1: AN {1/10/25G} P1: AN {1/10/25G}
P2: no AN
P2: no AN
P2: no AN
P2: AN {1G}
P2: AN {10G}
P2: AN {25G}
P2: AN {1/10G}
P2: AN {1/25G}
P2: AN {10/25G}
P2: AN {1/10/25G}
Note:
Use a supported optical transceiver or direct attached copper cable to achieve 1 Gbps