CVPM02, CVPM05, CVFM04 User Guide
CVPM02, CVPM05 Power Modules | CVFM04 Cache Module
6. Carefully press the CVFM04 module onto the MegaRAID controller so that the two connectors are firmly joined.
7. Secure the CVFM04 module to the MegaRAID controller by screwing in the two screws from the top side of
the controller.
The standoffs are threaded at both ends, and the screws thread from the back side of the controller into the board-to-
board standoffs.
NOTE
Center the screwdriver carefully to avoid stripping the screwhead. Do
not
overtighten the screws.
Installing the Clip on the Remote Mount Board
Follow these steps to install the clip directly on the BBU-BRACKET-05 remote mount board.
1. Remove the clip and the remote mount board module from the package.
2. With the remote mount board on a flat, clean, static-free surface, ground yourself, and make sure that the system
is grounded.
3. Hold the clip so that the screw holes on the clip align with the screw holes on the remote mount board, as shown in the
following figure.
Figure 3: Install the Clip on the Remote Mount Board
Broadcom
CVPM02-05-CVFM04-UG101
9